F0880 F880: Provide and implement an infection prevention and control program.
E

Failure to Follow Infection Prevention and Control Practices

San Gabriel Valley Medical Ctr D/p SnfSan Gabriel, California Survey Completed on 03-28-2025

Summary

The facility failed to adhere to standard infection prevention and control practices for five of thirteen sampled residents, as evidenced by multiple direct observations and staff interviews. In one instance, a resident with severe cognitive impairment and total dependence for activities of daily living was observed with a Foley catheter drainage bag resting on the floor and not covered with a dignity bag, contrary to the care plan and facility policy. Both a registered nurse and the interim director of nursing confirmed that the drainage bag should not be on the floor due to infection control concerns and that it should be covered for both dignity and infection prevention. During medication administration and dressing changes, two LVNs did not change gloves or perform hand hygiene between tasks. One LVN, while administering medications to a resident with severe cognitive impairment and multiple comorbidities, picked up a medication bottle from the floor with gloved hands, continued preparing medications without changing gloves, touched various surfaces and the resident’s linens, and administered medications and eye drops—all without changing gloves. The LVN admitted to not being aware of the need to change gloves between tasks. Another LVN, during a G-tube dressing change and medication administration for two different residents, failed to change gloves after touching potentially contaminated surfaces, such as the resident’s clothes and their own mask, before proceeding with invasive procedures. Both LVNs acknowledged during interviews that they should have changed gloves to prevent possible contamination. Additionally, the facility did not ensure that medical equipment was properly cleaned and disinfected. A feeding pump used by a resident with chronic respiratory failure and end-stage ALS was observed with visible brown/yellow stains, and a CNA confirmed that the equipment should be cleaned daily. The infection prevention nurse also stated that daily cleaning of medical equipment is essential for infection control. Facility policies reviewed supported the need for proper hand hygiene, glove changes, and daily cleaning of patient care equipment, but these were not followed in the observed instances.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Use Required Enhanced Barrier Precautions During PICC Line Medication Administration
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident receiving IV meropenem via a PICC line for septic shock related to a UTI had an active care plan and door signage requiring enhanced barrier precautions, including use of gown and gloves for high-contact care and device care to reduce MDRO transmission. During an observed medication administration, an LPN performed hand hygiene, donned gloves, accessed and flushed the PICC line, and administered the antibiotic without donning a gown, later stating she had forgotten to do so. The IP confirmed that a gown was required before administering the antibiotic, and this failure created the potential for infection spread.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Enhanced Barrier Precautions, Hand Hygiene, and Laundry Handling Practices
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Surveyors found that staff did not consistently follow EBP, hand hygiene, and clean laundry handling practices. During tracheostomy care for a resident, a nurse wore gloves and a mask but did not don a gown or change gloves before placing clean gauze and the trach cannula. In a separate case, after completing wound care for another resident, the same nurse manipulated a suprapubic catheter tubing while still holding wound supplies and then left the room without performing hand hygiene. Additionally, a housekeeping/laundry staff member removed residents’ personal items from a covered cart and carried them over the shoulder between halls without keeping the items covered. These actions did not follow facility policies requiring targeted gown and glove use for high-contact care, proper hand hygiene around invasive devices and dressings, and keeping laundry carts covered between rooms.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inadequate Hand Hygiene and Environmental Cleaning in Infection Control Program
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Surveyors found that residents were served meals in the dining room without being offered required hand hygiene before eating, despite facility policy mandating handwashing or alcohol-based hand rub use before handling food. A CNA and the DON both acknowledged that residents’ hands should have been sanitized prior to meals. Additional observations showed a housekeeper transporting clean gowns uncovered in a hallway and significant visible buildup of white and grey fuzzy substances on pipes, wires, equipment, and chemical buckets in the laundry area, with the housekeeper stating there was no formal cleaning schedule in place.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Perform Hand Hygiene and Change Gloves Between Perineal and Other Care Tasks
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident receiving wound and catheter care was assisted by an RN and a CNA who donned gowns, N95 masks, and gloves before entering the room. After perineal and catheter care, the RN did not change gloves or perform hand hygiene and continued to separate the resident’s labia, adjust clothing, handle the bed pad, reposition the resident, and operate the bed controls with the same soiled gloves. This practice conflicted with the facility’s infection control policy, which requires removal of soiled gloves and handwashing when moving from dirty to clean tasks and after contact with potentially infectious material.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use Required Gowns Under Enhanced Barrier Precautions During High-Contact Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to follow Enhanced Barrier Precautions (EBP) by not wearing gowns during high-contact care activities for two residents on EBP. In one case, a nurse provided catheter care to a resident with an EBP sign and available PPE but wore only gloves, later stating she believed gowns were needed only when changing the catheter. In another case, two NAs used a mechanical lift to transfer a resident with a gastrostomy tube, again with EBP signage and PPE present, but wore only gloves; one NA stated he did not view transferring as high-contact care, and the other reported she did not always use gowns for transfers. These actions conflicted with the facility’s EBP policy and posted instructions requiring both gown and gloves for high-contact activities such as catheter care and transfers.

Fine: $59,580
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Legionella Water Management and Monitoring Policy
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility did not follow its Legionella water management policy by failing to complete and document required monthly water temperature testing and flushing over a three‑month period. Review of water temperature monitoring logs showed no evidence of the mandated testing, and the interim Maintenance Director confirmed that no documentation existed for those months. This represented a failure to implement the facility’s infection prevention and control program as written.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙