F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
K

Failure to Assess and Document Bed Rail Use and Entrapment Risk

Madison Health And Rehabilitation CenterMadison, Wisconsin Survey Completed on 03-25-2025

Summary

The facility failed to ensure that alternatives were attempted prior to the installation and use of bed rails, including side rails and enabler bars, for multiple residents. There was no system in place to assess the risk of entrapment between the mattress and side rail, and the facility did not identify or recognize that the use of side rails with air mattresses increases the risk for entrapment. Documentation was lacking for assessments, risks and benefits discussions, alternatives tried, measurements, and informed consent for the use of side rails for several residents, both cognitively intact and impaired, some of whom had activated powers of attorney. Surveyors observed numerous residents using air mattresses with side rails or enabler bars without evidence of prior assessment or documentation. Interviews with facility staff, including the DON, Maintenance Director, and PTA, confirmed that there was no process or assessment in place for side rails prior to a specific date. Staff also indicated that side rails were often left on beds after resident discharge and used for subsequent residents without evaluation. In several cases, residents or their representatives reported not being informed of the risks and benefits or being asked for consent prior to the use of side rails or enabler bars. Specific examples included residents with significant mobility impairments, cognitive deficits, and histories of falls who were observed with air mattresses and side rails or enabler bars, but without any documentation of risk assessment, alternatives attempted, or informed consent. In some cases, gaps between the mattress and side rails were observed to be large enough to pose a risk of entrapment. The facility's own policy and FDA recommendations regarding bed rail safety and the increased risk of entrapment with air mattresses were not followed prior to the surveyors' findings.

Penalty

Inspection fine: $177,862
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0700 citations
Failure to Assess and Obtain Consent Before Bed Rail Use
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

Failure to assess and obtain consent before bed rail use for two residents. Two cognitively intact residents with diagnoses including AFib, HTN, arthritis, CAD, and HF were observed with bed rails on their beds even though their MDSs indicated no bedrail use. Both records lacked a bedrail assessment, consent, and education, and the DON confirmed no assessment had been completed before the rails were installed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Bed Rail Entrapment Risk and Mattress Settings
J
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

A resident with severe cognitive impairment and total dependence for care fell from bed after an air mattress was set too high for the resident’s weight, causing the mattress to overinflate and push the resident into a siderail. The resident’s arm became trapped in the rail and the resident sustained neck and sternum injuries. The record also showed no siderail entrapment assessment for the resident, and multiple other residents with air mattresses and siderails also lacked documented side rail assessments.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Reassess Bed Siderail Safety Led to Resident Injury
G
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

A facility failed to complete ongoing reassessments of bed siderail safety for a resident with severe cognitive impairment and total dependence for bed mobility. The resident continued using the siderails for months without the required review, and later developed bruising and a traumatic posterior shoulder dislocation after the arm was reportedly caught in the rail. An internal investigation and later assessment found the siderails were unsafe and no longer indicated.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess and Obtain Consent for Bed Rail Use
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

Failure to Assess and Obtain Consent for Bed Rail Use: Two residents had one-quarter bed rails in place with physician orders for positioning and mobility, but the clinical record lacked documented bed rail safety assessments and signed informed consent. One resident had moderately impaired cognition and the other had severely impaired cognition; both were observed with the rails up and locked in place. The ADM and DON acknowledged the assessments and consents were missed, and staff stated the required documentation should have been completed before bed rail use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Document Alternatives and Monitor Bed Rail Use
D
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

A resident with acute and chronic respiratory failure with hypoxia, Type 2 DM with hyperglycemia, generalized muscle weakness, and impaired cognition was placed in four locked bed rails for fall risk. The record showed only one alternative intervention, one-to-one activities and supervision, with no documented evidence explaining why it was ineffective, and the DON stated there was no documented active order for a low bed or other alternative. The resident was observed asleep with all four bed rails up and locked, and the care plan and active orders did not show monitoring for safe bed rail use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Bed Rail Entrapment Risk
J
F0700 F700: Try different approaches before using a bed rail. If a bed rail is needed, the facility must (1) assess a resident for safety risk; (2) review these risks and benefits with the resident/representative; (3) get informed consent; and (4) Correctly install and maintain the bed rail.
Short Summary

Failure to Assess Bed Rail Entrapment Risk: A resident with severe cognitive impairment and multiple medical conditions was placed in a bed with assist rails without documented assessment for appropriateness, documented alternatives, or informed consent. Staff later found the resident with his head and neck trapped between the mattress and the assist bar, unresponsive and not breathing, and CPR was started before EMS transported him to the hospital. The resident was admitted with cardiac arrest and diffuse hypoxic injury and later expired.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Wisconsin

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Wisconsin — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.