Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0161
F

Non-Compliance with Sprinkler System Requirements in Attic Space

Negaunee, Michigan Survey Completed on 04-03-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to ensure that its building construction type and number of stories complied with the requirements outlined in Table 19.1.6.1, as required unless otherwise permitted by specific exceptions. During a record review and interview, it was found that the dry sprinkler system in the attic space did not pass inspection because the system was capped and only six sprinkler heads were operational. The annual dry sprinkler inspection report confirmed this deficiency, and the Maintenance Director verified that the attic sprinkler system was not functioning properly. This failure is in violation of the requirement that all LTC facilities be fully sprinklered and maintain their systems as mandated by 73 CFR 47075.

Plan Of Correction

1. The facility did not maintain the dry sprinkler system in proper working condition throughout the building. 2. A malfunctioning dry sprinkler system poses a risk to the safety of all residents, staff, and visitors in the event of a fire emergency. 3. Corrective actions have been completed as follows: - Excel Fire Protection replaced the 3-inch and 4-inch system piping. - Superiorland Electronics installed a second air compressor and replaced 12 feet of main sprinkler piping. - The sprinkler system was flooded and tested, revealing two leaks (located above a resident room and in the boiler room); both have been repaired. - Superiorland Electronics will conduct a trip test to confirm the system is functioning properly. - The Maintenance Director has been educated on the critical importance of maintaining the dry sprinkler system in working order. - Superiorland Electronics will complete the hydrostatic testing of the system by 5/23/25. 4. The Maintenance Director is responsible for ongoing monitoring of the dry sprinkler system to ensure it remains operational at all times and will report system status and maintenance updates to the Quality Assurance (QA) Committee.