Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
NY State Tag
E

Failure to Maintain Smoke Barriers as per NFPA 101

Fort Edward, New York Survey Completed on 12-06-2024

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain smoke barriers in accordance with the National Fire Protection Association (NFPA) 101 Life Safety Code 2012 edition. Specifically, the G-wing east smoke barrier wall in Building #1 was not continuous from the floor to the underside of the roof and through all concealed spaces, and the fire-resistance rating was not maintained as required. During observations, a 12-inch by 12-inch hole in the smoke barrier wall was found filled with insulation but not fire-protected. This deficiency was confirmed during an interview with the Maintenance Supervisor, who acknowledged the issue and stated that they would address the fire sealing of the space in the G-wing smoke barrier wall.

Plan Of Correction

Plan of Correction: Approved January 10, 2025 1. G wing east smoke barrier wall penetration will be sealed using appropriate fire seal. Due to the location of this area, it is not accessible for hand-application and specialized equipment is required. NOTE – this penetration was from original construction and is located above a series of pipes and conduits offering no means of direct access. 2. All smoke barrier walls in building #1 (identified as G and D wings) will be inspected to identify any other penetrations lacking appropriate fire protection. 3. All maintenance staff will be informed of the requirements for smoke walls and fire protection sealant in written form, with signature attesting to receipt and understanding. Existing standards for new work resulting in penetrations will be included in education. 4. Director of Plant Operations will verify all smoke barrier walls have been visually inspected and report the findings to Quality Assurance/Performance Improvement committee. New work resulting in penetrations to smoke walls will be visually inspected at completion; any remaining penetrations will be reported through Safety Committee. Responsible: Director of Plant Operations

An unhandled error has occurred. Reload 🗙