F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
E

Inadequate GT Care and Infection Control Lapses

Country Oaks Care CenterPomona, California Survey Completed on 03-06-2025

Summary

The facility failed to provide adequate gastrostomy tube (GT) treatment and services for two residents receiving enteral feedings. For Resident 40, the GT was observed disconnected from the feeding pump, resulting in enteral feeding spilling onto the floor. This incident occurred after Licensed Vocational Nurse (LVN) 7 had powered off the GT feeding pump and disconnected the resident for a bed bath, but the disconnection was not communicated to the incoming Certified Nursing Assistant (CNA) 4. The Director of Nursing (DON) acknowledged that such disconnections could lead to a loss of track of the amount of enteral feeding received, potentially causing weight loss. For Resident 20, the facility failed to follow infection control precautions, as the tip of the resident's GT touched the floor. Additionally, CNA 1 improperly handled the GT feeding pump by disconnecting the feeding and turning the machine on and off, actions that were against the facility's policy. The DON confirmed that CNAs were not permitted to disconnect or operate the GT feedings and emphasized the importance of preventing GT tubing from touching the floor to avoid contamination. Both residents had severe cognitive impairments and were dependent on staff for various activities of daily living. Resident 40 had a history of chronic respiratory failure and dysphagia, while Resident 20 had a diagnosis related to gastrostomy and swallowing difficulties. The facility's policy on the care and treatment of feeding tubes, revised in December 2022, was not adhered to, leading to these deficiencies.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incomplete Enteral Feeding Order for Resident with G-Tube
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, dysphagia, and malnutrition had an enteral feeding order that omitted the formula strength and the administration method. The chart showed the resident was receiving Isosource 1.5 cal bolus feedings, but the active order only stated enteral feed via g-tube. The MDS Coordinator, LVN, and DON all acknowledged the order was incomplete, and the facility policy required enteral nutrition orders to include the product and administration method.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify GT Placement Before Medication Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, GERD, interstitial pulmonary disease, and dementia was observed receiving medications via the GT without the nurse confirming tube placement. The LVN stated she did not check GRV before administering the medications, and the RN and DON stated GT placement and residuals should be checked prior to medication administration, although the facility policy did not include GRV checking.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inadequate G-tube care and enteral feeding documentation
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Inadequate G-tube care and enteral feeding documentation. A resident with CVA-related hemiplegia and dysphagia had orders for NPO status, continuous Jevity 1.5 via G-tube, water flushes, residual checks every shift, and oral care, but the record lacked an order for tube placement verification or shift site care. MAR/TAR review showed no consistent documentation of G-tube site care or residual checks, water flushes were not always documented as ordered, and feeding amounts were recorded in two places with inconsistent entries; nursing notes were also not present for every shift.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Delayed G-tube Feeding Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a g-tube, severe cognitive impairment, and dependence on staff for all nutrition and hydration did not receive continuous tube feeding at the ordered start time. The feeding pump was observed off while the resident was away from his room and remained off after he returned from the Day Center; an LVN later connected the feeding after changing the g-tube dressing. Staff stated the resident often returned after the ordered start time and was therefore not hooked up as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Resident with G-tube was fed while lying flat
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube was observed lying supine and below 30 degrees while enteral feeding was running. A CNA said the resident was lower than she should have been during the feeding and that the tube feeding should be turned off when repositioning is needed. An LVN later confirmed the resident should not be lying flat during feeding, paused the tube feeding, and said the resident needed assistance to be safely elevated; the DON stated the head should be elevated above 30 to 45 degrees and never flat during feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Verify G-Tube Placement Before Medications and Water Administration
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Failure to Verify G-Tube Placement Before Medications and Water Administration: An LPN administered crushed meds and water through a resident’s PEG tube without routinely checking tube placement first. The resident had dysphagia, cognitive impairment, and received most calories and fluids via the feeding tube. The RN and DON also indicated uncertainty about whether placement checks were still required, and no provider order exempting the resident from placement verification was found, despite the facility policy requiring placement checks before tube feedings and meds.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.