Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
NY State Tag
E

Deficiencies in Smoke Barrier Wall Maintenance

Williamsville, New York Survey Completed on 12-06-2024

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

During a Life Safety Code survey, it was observed that the smoke barrier walls in Unit 5 of the facility were not properly maintained. Specifically, the walls were not complete from floor to roof deck, lacked a 30-minute fire resistance rating, and were not designed to resist the passage of smoke due to penetrations. These deficiencies were identified in several locations: a two-inch by one-inch penetration near a steel support beam above the smoke barrier doors near Resident Room 519, a four-inch by two-inch area filled with mineral wool but not sealed with fire-rated material above the smoke barrier doors near Resident Room 522, and a five-inch by three-inch penetration near plumbing pipes below the sink in the bathroom of Resident Room 522. Interviews with the Maintenance Director revealed a lack of awareness regarding the penetration below the sink in Resident Room 522, and it was noted that no recent plumbing work had been conducted in that area. Furthermore, the Maintenance Director admitted that while the maintenance staff checked the facility's smoke barrier walls, there was no documentation available for these checks. This lack of documentation and awareness contributed to the failure in maintaining the smoke barrier walls as required by the facility's Smoke Barrier Penetration Policy.

Plan Of Correction

Plan of Correction: Approved December 30, 2024 1. The Unit 5 corridor ceiling penetration next to a steel support beam near Resident Room 519 was sealed by Maintenance. The Unit 5 corridor ceiling penetration located by the corrugated roof deck and the smoke barrier wall above the smoke barrier doors near Resident Room 522 was sealed with a fire rated material by Maintenance Director. The First Floor on Unit 5 penetration near plumbing pipes that were installed through the smoke barrier wall below the sink in the bathroom of Resident Room 522 was sealed with fire rated material by Maintenance Director. 2. All residents are at risk for the deficient practice of smoke barrier walls not being maintained. 3. All smoke barrier walls will be audited for penetrations. Any deficient practice will be repaired. 4. Administrator educated Maintenance Director and Maintenance Tech on Smoke barrier walls and 30 minute resistance rating. 5. The facility will conduct quarterly audits on Smoke barrier walls. Any deficient practices will be repaired and brought to QAPI for further review. Person Responsible: Maintenance Director

An unhandled error has occurred. Reload 🗙