Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
NY State Tag
F

Deficiency in Fire-Rated Door Frames in Emergency Exit Stairwells

Cortland, New York Survey Completed on 01-17-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility was found to have deficiencies in maintaining vertical openings during a Life Safety Code recertification survey. Specifically, eight emergency exit stairwell door frames across various floors lacked fire-rated labels. These included the first, second, and third-floor south emergency exit stairwells, the second and third-floor northwest emergency exit stairwells, the second and third-floor northeast emergency exit stairwells, and the second-floor center emergency exit stairwell. The absence of fire-rated labels on these door frames was identified during observations conducted on January 13, 2025. The Director of Maintenance was interviewed and revealed that they were unaware of the missing fire-rated labels on the door frames of the emergency exit stairwells. The Director stated that the door frames had been inspected annually by a third party in 2023 and 2024, but the inspection forms did not include a section to document the fire rating of the door frames. The Director acknowledged the requirement for the door frames to have a 1-hour fire-rated label and recognized the importance of this for the safety of residents and staff.

Plan Of Correction

Plan of Correction: Approved February 10, 2025 The following corrective action(s) will be accomplished for those residents found to have been affected by the deficient practice: - Ensured vertical openings maintained and fire rating labels placed on the first-floor south emergency exit stairwell, second-floor south emergency exit stairwell, third-floor south emergency exit stairwell, second-floor northwest emergency exit stairwell, third-floor northwest emergency exit stairwell, second-floor northeast emergency exit stairwell, third-floor northeast emergency exit stairwell, and the second-floor center emergency exit stairwell. The facility will identify other residents having the potential to be affected by the same deficient practice and the following corrective action will be taken: - Audit vertical openings and fire rated doors for fire rated labels. The following measures will be put in place and/or systemic changes will be made to ensure that the deficient practice does not recur: - Education of fire rated doors to have label to door tracking to maintenance staff. The corrective action(s) will be monitored to ensure the deficient practice will not recur: - Audit all fire rated doors for vertical opening and fire rated labels x3 months 100%. The date for correction and the title of the person responsible for correction of each deficiency: - Date of Correction: 3/5/2025 - Person Responsible: Director of Maintenance.