F0880 F880: Provide and implement an infection prevention and control program.
E

Infection Control Deficiencies in Resident Care

La Dora Nursing And Rehabilitation CenterBedford, Texas Survey Completed on 02-13-2025

Summary

The facility failed to maintain proper infection prevention and control measures, as evidenced by several observed deficiencies involving staff interactions with residents. In one instance, an LVN did not sanitize her hands after moving a resident's floor mat and before touching the bedside table containing medical items. She also failed to change her gloves after touching various surfaces before handling the resident's G-tube. This oversight was acknowledged by the LVN, who admitted to being nervous under observation and forgetting to change her gloves. Another deficiency was observed during wound care for a resident. An LVN, along with two CNAs, failed to prevent cross-contamination of care items. The wound care items were placed on a bedside table that was in contact with a privacy curtain, and the CNAs reached over the table to access PPE, allowing their gowns to touch the wound care items. Additionally, one CNA reached over the clean field to assist with the resident's foot, further risking contamination. The LVN admitted that the wound care field should have been kept clean and free from unnecessary access by staff. A third deficiency involved another LVN who did not sanitize a stethoscope before and after using it on a resident. The stethoscope was placed on the resident's stomach near a G-tube without prior cleaning, and it was returned to the medication cart without being sanitized. The LVN acknowledged forgetting to sanitize the equipment, which could have led to contamination. The DON confirmed that standard infection control precautions, including hand hygiene and equipment sanitization, were expected to be followed by all staff.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow EBP and Hand Hygiene During Incontinence Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Follow EBP and Hand Hygiene During Incontinence Care: A resident with a catheter, hospice care, heart failure, and a lumbar compression fracture had a care plan for EBP requiring gown and gloves for high-contact care. During incontinence care, a CNA provided care without a gown, touched the bed linens, curtain, and gown with a uniform, and handled stool-soiled items without changing gloves or performing hand hygiene. A second CNA assisted with turning and wiping stool but changed gloves without hand hygiene; an RN later stated the PPE and hand hygiene used were not appropriate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control and Enhanced Barrier Precautions Not Used During Wound Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control and EBP Not Used During Wound Care Three residents with open wounds received wound care from RNs without PPE, and there was no PPE or precaution signage outside their rooms. The nurses and leadership stated the residents were not on EBP because the wounds were not infected or were considered simple dressings, even though the facility policy required gown and glove use for wound care involving any skin opening requiring a dressing and identified complex/infected wounds as EBP indications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow EBP During Urinary Catheter Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to follow EBP during urinary catheter care: an LPN provided catheter care to a resident without wearing the required PPE gown, despite an EBP sign posted on the room door and gowns being available at the entrance. The nurse stated he wore a gown for contact precautions but not for EBP and was unaware a gown was required for catheter care; the IP, DON, and Administrator all stated a gown was expected for this high-contact activity.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete TB Testing on Admission
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident admitted for skilled nursing services did not have documented TB testing completed on admission. A T-spot was later drawn, but there was no record that the specimen was sent to the lab or that results were obtained. The DON stated the facility missed the resident during TB audit checks and that the sample was not processed because the lab form was not sent with it, despite the facility policy requiring TB screening and testing within 72 hours of admission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses With PEG Medication Administration and Oxygen Tubing Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to maintain infection control for two residents. An RN did not sanitize hands between glove changes while administering medication via a resident’s PEG tube, despite the resident being on EBP and having a care plan for tube feeding and meds via PEG. In another instance, a resident with respiratory failure had oxygen tubing left unbagged when not in use, even though staff stated it should be bagged to prevent contamination.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE in Contact Isolation Room
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with klebsiella, a UTI, MDR organism status, an indwelling urinary catheter, and IV access was on contact precautions with signage at the door requiring hand hygiene, gown, and gloves before entry. A CNA entered the room and answered the call light without PPE, and later stated she only used PPE for catheter care. The charge nurse and DON stated staff were expected to wear PPE whenever entering the contact isolation room.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Texas

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Texas — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙