Inadequate Training Leads to Improper Glucometer Disinfection
Summary
The facility failed to provide adequate orientation and training to agency nurses, leading to improper disinfection of glucometers between residents. Nurse #1, an agency nurse, used a shared glucometer without disinfecting it between residents, specifically for Resident #107, despite the presence of 18 residents with known bloodborne pathogens in the facility. This lack of disinfection posed a high risk of cross-contamination and potential exposure to bloodborne pathogens for residents without existing infections. The deficiency was further highlighted when Nurse #2, another agency nurse, demonstrated a lack of competency in the disinfection of individually assigned glucometers. Nurse #2 was unaware of the required wet contact time for disinfectant wipes, which is crucial for effective disinfection. Both nurses were not provided with specific training or orientation on glucometer disinfection procedures, as the facility assumed agency nurses were already trained in these competencies. Interviews with the Director of Nursing (DON) revealed that the facility's orientation packet for agency nurses did not include information on glucometer disinfection or storage. The DON acknowledged this oversight and the assumption that agency nurses were competent in these areas. The Medical Director also identified this as a training issue, indicating a need for better education on glucometer disinfection for all staff.
Removal Plan
- Comprehensive Glucometer Training and Competency Program: All licensed nurses must complete training and demonstrate competency before performing blood glucose monitoring.
- Competency Validation Process: Direct observation by nurse management of complete blood glucose monitoring procedure, proper hand hygiene and glove use, correct glucometer cleaning and disinfection technique, appropriate wet contact time monitoring, proper barrier use and storage procedures, return demonstration required for all steps, documentation of competency verification in employee file, no blood glucose monitoring permitted until competency validated.
- Ongoing Monitoring: The Director of Nursing maintains documentation of all completed competency validations, the staffing coordinator verifies completion of glucometer competency before scheduling.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.