F0880 F880: Provide and implement an infection prevention and control program.
K

Infection Control Deficiencies in C. Auris Outbreak Management

Vantage At Worcester LlcWorcester, Massachusetts Survey Completed on 02-11-2025

Summary

The facility failed to implement and maintain an effective infection prevention and control program on Unit #1, which specializes in the care of residents with tracheostomies and ventilators. The unit had an ongoing issue with the spread of Candida Auris (C. Auris), a highly contagious yeast that can cause severe infections. Staff were observed not following infection control practices, such as not wearing gowns during high-contact care activities, not performing hand hygiene at appropriate intervals, and using inappropriate cleaning products in areas with confirmed C. Auris cases. Several specific incidents were noted during the survey. A respiratory therapist was observed performing tracheal suctioning on a resident without wearing a gown, despite the resident being on Enhanced Barrier Precautions (EBP). The therapist admitted to forgetting to wear a gown, acknowledging the risk of exposure to respiratory secretions. Additionally, the therapist failed to perform hand hygiene between glove changes during a nebulizer treatment, mistakenly believing it was unnecessary when working with the same resident. Another resident's tracheostomy care was performed by a nurse without wearing a gown, which the nurse later admitted was a mistake. The facility also lacked a policy or process for cleaning and disinfecting areas where C. Auris was present. A housekeeper was observed using a deodorizer instead of an appropriate disinfectant on surfaces in a resident's room. The housekeeper later switched to using Oxivir, a product effective against C. Auris, after noticing the surveyor's presence. The housekeeping director confirmed that the facility had recently started using Oxivir for this purpose but acknowledged that the floor cleaner used, Quat 64, was not effective against C. Auris. The administrator was unaware of the ineffectiveness of the floor cleaner and deferred management of the outbreak to the Director of Nursing, who was in contact with an epidemiologist at the Department of Public Health.

Penalty

Fine: $159,248
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations in Ohio
Infection Control Failures in Tracheostomy Care, Glucometer Disinfection, and Catheter Management
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Surveyors identified multiple infection control failures involving three residents. During tracheostomy care for a resident with chronic respiratory failure and a trach, an RN removed soiled gloves after handling the inner cannula and dressing and then donned sterile gloves without performing required hand hygiene between glove changes before cleaning the stoma and applying a new dressing. In a separate incident, an RN performed a finger-stick blood glucose test on a diabetic resident using a shared glucometer and returned the device to the medication cart without disinfecting it, despite facility policy requiring decontamination of shared glucometers. Additionally, a resident with an indwelling urinary catheter was observed seated with the catheter drainage bag lying directly on the floor, contrary to facility policy that catheter bags and tubing be kept off the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Infection Control During Medication Administration
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A nurse was observed preparing multiple oral medications for a resident with depression, traumatic brain injury, anxiety, and impaired cognition by pushing tablets and capsules from unit-dose cards directly into her ungloved hand and then using her fingers to place them into a medication cup. In a follow-up interview, the RN confirmed this practice and acknowledged that the correct procedure is to dispense medications directly from the card into the cup, contrary to the facility’s medication administration policy requiring adherence to good nursing principles and practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Enhanced Barrier Precautions During Catheter Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A deficiency occurred when staff failed to follow enhanced barrier precautions (EBP) for a resident with an indwelling urinary catheter. The resident had severe cognitive impairment, required total assistance with ADLs, and had a care plan and MD orders specifying EBP due to the catheter. An EBP cart with PPE was available outside the room, but during observed catheter care a CNA did not don a gown, despite acknowledging that the resident was supposed to be on EBP. Facility policy required EBP for residents with urinary catheters for the duration of their stay.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use Required PPE for Resident on Enhanced Barrier Precautions
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with toxic encephalopathy, Parkinson’s disease, and a gastrostomy, who was cognitively impaired and dependent for toileting and dressing, had active orders and a care plan requiring Enhanced Barrier Precautions (EBP) with gown and glove use during high-contact ADL care, toileting, and linen changes. Surveyors observed a CNA repeatedly entering and exiting the resident’s room, which was posted for EBP, without wearing a gown while providing perineal care, toileting assistance, dressing, and changing bed linens. The CNA acknowledged the resident was on EBP, that no PPE supply was available near the room, and that she did not wear a gown, contrary to the facility’s EBP policy requiring gowns and gloves for such high-contact care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Widespread Infection Control and Water Management Failures
F
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Surveyors identified multiple infection prevention and control failures involving several residents, including a resident with pneumonia and impaired cognition whose soiled linens and used brief were left on the floor during care, and residents with diabetes whose blood glucose checks and insulin administration were performed by LPNs who did not perform hand hygiene and did not properly disinfect shared glucometers between uses. Additional residents receiving oral and nasal medications had their medications prepared and administered by LPNs who did not wash their hands before or after resident contact or before reentering the medication cart. A severely cognitively impaired resident with a chronic sacral wound and an indwelling catheter, care planned for Enhanced Barrier Precautions, received high-contact care from two CNAs who did not don gowns and did not perform hand hygiene while changing briefs, handling catheter tubing and bags, and transferring the resident. The facility also failed to carry out its Legionella Water Management Program, as the Administrator confirmed that required Legionella testing of the water system was either limited to ice machines in one year or not performed at all in the following year, despite the presence of unused rooms with stagnant water.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Clean Reusable Equipment and Maintain Clean Linen Storage
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

An LPN failed to clean reusable vital sign equipment between two residents on enhanced barrier precautions, including one on contact precautions for Klebsiella pneumoniae, and reached into a red biohazard bin containing soiled gowns with bare hands after removing PPE. On a resident hallway, a linen cart was left uncovered with clean towels and gowns exposed, and a dirty towel with brown spots was found on top of the clean linen cart, with a bag of soiled items placed directly next to it on the floor. Staff later acknowledged that reusable equipment should be cleaned between residents and that linen carts should remain covered, consistent with facility infection control policies.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

65.1% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 55 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙