F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
D

Failure to Document Pre-Dialysis Vitals

Mountain City Rehab CenterFrostburg, Maryland Survey Completed on 11-26-2024

Summary

The facility staff failed to obtain and document pre-dialysis treatment records for a resident with end-stage renal disease who required hemodialysis. The resident had a hospital discharge summary indicating the need for dialysis three times a week. Despite having a system in place for documenting pre-dialysis vitals and conditions, the facility did not record these vitals on several occasions, including specific dates in October and November. The dialysis communication forms, which were supposed to be filled out entirely and sent with the resident, were incomplete, lacking vital signs and other necessary information. Interviews with facility staff revealed that nurses were expected to record the resident's temperature, pulse, respiration, and blood pressure before dialysis and complete the communication form. However, this was not consistently done, as evidenced by feedback from the dialysis center noting the absence of pre-dialysis information. The Director of Nursing confirmed the expectation for nurses to assess and document the resident's vitals before each dialysis session, highlighting a lapse in following established procedures for ensuring safe and appropriate dialysis care.

Penalty

Inspection fine: $33,121
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0698 citations
Missed Phosphorus Binder Medications for Dialysis Resident
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with ESRD, renal osteodystrophy, and dialysis dependence did not receive prescribed phosphorus binders as ordered. Velphoro was not given for an entire month and Sevelamer was given on only a few days, with charting repeatedly stating the meds were awaiting pharmacy delivery or unavailable. Staff gave inconsistent explanations, and the dialysis center manager stated the resident had not been receiving the meds as prescribed and that Sevelamer should have been discontinued.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete Dialysis Communication Records
E
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with ESRD, CHF, and DM2 had orders for dialysis three times weekly, and the care plan called for open communication with the dialysis center. However, multiple dialysis communication sheets were missing from the clinical record even though the MAR showed the resident went to dialysis on those visits, and the DON confirmed the records were absent.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete dialysis communication and access site monitoring
E
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

Incomplete dialysis communication and access site monitoring: The facility failed to maintain complete dialysis communication records for three residents with ESRD or dialysis dependence, and failed to document ordered AV fistula checks for two residents. One resident had conflicting AV fistula orders, while another had repeated missing thrill and bruit documentation on the TAR. The DON and NHA confirmed the documentation failures.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Dialysis care, I&O monitoring, and ordered labs not completed
E
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A facility failed to complete required dialysis-related care for three residents receiving hemodialysis. For one resident, the AV shunt was not assessed and documented before and after dialysis on multiple occasions. For two other residents, ordered I&O monitoring was not consistently recorded each shift, and one resident’s CBC and BMP were completed monthly instead of weekly as ordered by the MD.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Dialysis Access Monitoring Not Performed Correctly
D
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

A resident with ESRD and diabetes received dialysis, but staff failed to monitor the dialysis access correctly after the resident’s access changed from a CVC in the right chest to an AV fistula in the left upper arm. Nursing staff documented checks for bleeding and post-dialysis status, but were not aware of the fistula, did not assess for bruit and thrill, and did not have direction to avoid BP checks on the access arm. The DON stated staff should know the correct access site and assess it based on the type and location of access.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Dialysis care, transportation, documentation, and fluid restriction failures
E
F0698 F698: Provide safe, appropriate dialysis care/services for a resident who requires such services.
Short Summary

The facility failed to provide consistent dialysis-related care for two residents with ESRD. One resident missed scheduled dialysis because transportation did not arrive, and staff did not complete the dialysis communication record with pre- and post-dialysis assessments. Another resident had missing dialysis sign-out documentation, a missing dialysis communication record entry, and exceeded a physician-ordered 1000 ml fluid restriction on multiple days, while staff and the resident stated the restriction was not known to them.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Maryland

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Maryland — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.