Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0161
C

Building Construction Deficiency Due to Unprotected Structural Elements

Philadelphia, Pennsylvania Survey Completed on 01-22-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain building construction requirements, as evidenced by unprotected structural steel columns and beams above the suspended ceiling assemblies and pan-style ceiling diffusers lacking full 'blanket' protection. This resulted in the building being classified as unprotected ordinary construction. The building, classified as two stories, exceeds the maximum height allowed for unprotected ordinary construction by one story. This deficiency was confirmed during an exit interview with the Facility Administrator and Maintenance Director.

Plan Of Correction

The facility was evaluated by an engineering firm in 2018. The evaluation determined that the building is permitted to be of Type II (000) construction, which means that the steel in the building is permitted to be non-rated and unprotected. An analysis of the facility structure type was conducted by an engineer. The analysis provided concluded that the "construction type of the two-story, sprinkler protected, existing health care building is permitted to be Type II (000)." Type II (000) is an unprotected non-combustible construction. The facility has been classified as a Type III (200), unprotected ordinary construction. A request for a Time Limited Waiver was submitted to the Director of Safety Inspection on 9/8/21, to last through 1/1/2025. The FSES worksheets will be reviewed and revised by an engineer to identify if alternative corrections will be needed. The FSES worksheets (5.5) from the 2010 edition of the NFPA Guide on Alternative approaches to Life Safety will be included in the analysis.