Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0541
E

Fire Protection Deficiencies in Linen Chutes

Lima, Pennsylvania Survey Completed on 02-04-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain the fire protection rating for linen chutes, as evidenced by several deficiencies observed during a survey. On multiple floors, including the second, third, fourth, seventh, eighth, and tenth, the rubbish and laundry chute doors in the soiled utility rooms were found to be non-compliant. Specifically, the chute doors on the second and third floors failed to positively latch, while the chute door on the fourth floor was propped open by a lining cart. Additionally, the chute doors on the seventh, eighth, and tenth floors failed to close and latch properly. These deficiencies were confirmed during an exit interview with the Maintenance Director, who acknowledged the issues with the chute doors. The failure to maintain the fire protection rating for these chutes affects six out of fifteen levels in the facility, indicating a significant lapse in maintaining fire safety standards as required by NFPA 101. The report does not mention any corrective actions or plans to address these deficiencies.

Plan Of Correction

Plan of Correction: Preparation and submission of this POC is required by State and Federal law. This POC does not constitute an admission for purposes of general liability, professional malpractice, or any other court proceedings. K 0541-a Door was repaired to positive latch. Door will be monitored weekly for 1 Quarter by a maintenance department designee to ensure this condition is not replicated. K 0541-b Door was repaired to positive latch. Door will be monitored weekly for 1 Quarter by a maintenance department designee to ensure this condition is not replicated. K 0541-c Linen chute door was closed and Facility staff will be educated about the hazards of propping doors open. Door will be monitored weekly for 1 Quarter by a maintenance department designee to ensure this condition is not replicated. K 0541-d Door will be repaired to positive latch. Door will be monitored weekly for 1 Quarter by a maintenance department designee to ensure this condition is not replicated. K 0541-e Door will be repaired to positive latch. Door will be monitored weekly for 1 Quarter by a maintenance department designee to ensure this condition is not replicated. K 0541-f Door will be repaired to positive latch. Door will be monitored weekly for 1 Quarter by a maintenance department designee to ensure this condition is not replicated.