F0880 F880: Provide and implement an infection prevention and control program.
D

Failure to Change Oxygen Tubing as Per Policy

Kei-ai South Bay Healthcare CenterGardena, California Survey Completed on 01-13-2025

Summary

The facility failed to adhere to its infection prevention and control program by not changing the oxygen tubing for Resident 66 within the required seven-day period. Resident 66, who has chronic obstructive pulmonary disease, heart failure, and chronic kidney disease, was observed with oxygen tubing dated 12/18/2023, which had not been changed by 12/26/2023. This oversight was confirmed through interviews with the Licensed Vocational Nurse, Assistant Director of Nursing, and Infection Preventionist Nurse, all of whom acknowledged the importance of changing the tubing weekly to prevent infection. The facility's policy, as outlined in their Infection Prevention and Control Program and Respiratory Therapy-Prevention of Infection procedures, mandates the change of oxygen cannula and tubing every seven days to prevent infection. The failure to comply with this policy placed Resident 66 at risk for infection, as confirmed by the staff interviews and the facility's documented procedures.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Failure to Follow EBP and Hand Hygiene During Incontinence Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Follow EBP and Hand Hygiene During Incontinence Care: A resident with a catheter, hospice care, heart failure, and a lumbar compression fracture had a care plan for EBP requiring gown and gloves for high-contact care. During incontinence care, a CNA provided care without a gown, touched the bed linens, curtain, and gown with a uniform, and handled stool-soiled items without changing gloves or performing hand hygiene. A second CNA assisted with turning and wiping stool but changed gloves without hand hygiene; an RN later stated the PPE and hand hygiene used were not appropriate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control and Enhanced Barrier Precautions Not Used During Wound Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control and EBP Not Used During Wound Care Three residents with open wounds received wound care from RNs without PPE, and there was no PPE or precaution signage outside their rooms. The nurses and leadership stated the residents were not on EBP because the wounds were not infected or were considered simple dressings, even though the facility policy required gown and glove use for wound care involving any skin opening requiring a dressing and identified complex/infected wounds as EBP indications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow EBP During Urinary Catheter Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to follow EBP during urinary catheter care: an LPN provided catheter care to a resident without wearing the required PPE gown, despite an EBP sign posted on the room door and gowns being available at the entrance. The nurse stated he wore a gown for contact precautions but not for EBP and was unaware a gown was required for catheter care; the IP, DON, and Administrator all stated a gown was expected for this high-contact activity.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incomplete TB Testing on Admission
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident admitted for skilled nursing services did not have documented TB testing completed on admission. A T-spot was later drawn, but there was no record that the specimen was sent to the lab or that results were obtained. The DON stated the facility missed the resident during TB audit checks and that the sample was not processed because the lab form was not sent with it, despite the facility policy requiring TB screening and testing within 72 hours of admission.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses With PEG Medication Administration and Oxygen Tubing Storage
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

The facility failed to maintain infection control for two residents. An RN did not sanitize hands between glove changes while administering medication via a resident’s PEG tube, despite the resident being on EBP and having a care plan for tube feeding and meds via PEG. In another instance, a resident with respiratory failure had oxygen tubing left unbagged when not in use, even though staff stated it should be bagged to prevent contamination.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use PPE in Contact Isolation Room
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident with klebsiella, a UTI, MDR organism status, an indwelling urinary catheter, and IV access was on contact precautions with signage at the door requiring hand hygiene, gown, and gloves before entry. A CNA entered the room and answered the call light without PPE, and later stated she only used PPE for catheter care. The charge nurse and DON stated staff were expected to wear PPE whenever entering the contact isolation room.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙