F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Failure to Maintain Adequate Stock of Prescribed Gastrostomy Tubes

The Paramount At Somers Rehab And Nursing CenterSomers, New York Survey Completed on 11-07-2024

Summary

The facility failed to ensure that a resident who was fed by enteral means received the appropriate treatment and services to prevent complications. Specifically, the facility did not have the physician-prescribed gastrostomy tube size available for Resident #182, who was admitted with diagnoses including aphasia, respiratory failure, and gastrostomy status. The resident's care plan required a specific size of gastrostomy tube, but the facility ran out of the necessary 18-gauge gastrostomy tubes, leading to complications in the resident's care. On July 20, 2024, the resident's g-tube balloon broke, and the g-tube came out. The facility did not have the prescribed 18-gauge gastrostomy tube available, and attempts to use a 20-gauge tube were unsuccessful. As a temporary measure, an 18 French Foley catheter was inserted, and the resident was sent to the hospital for a new tube. On July 22, 2024, a 14-gauge gastrostomy tube was inserted because the facility still did not have the correct size in stock, which may have caused the resident's abdominal opening to become smaller. Interviews with facility staff revealed that the inventory management system was inadequate, as the Director of Housekeeping and Central Supply did not maintain records of inventory levels, leading to a shortage of the necessary gastrostomy tubes. The staff was unaware of how long the stock had been depleted, and the facility's purchasing process was delayed, contributing to the deficiency in care for Resident #182.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Unlabeled Tube Feeding Bags
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a G-tube and diagnoses including stroke and pneumonitis had tube feeding ordered at 60 ml/hr, and the care plan identified increased nutritional risk related to gastric tube use. Staff observed the tube feeding bag hanging with an additional water bag, and both bags were not labeled with the resident’s name, formula, rate, date, or time hung; an RN and an LPN confirmed the unlabeled setup.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Placement Not Verified Before Use
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with quadriplegia, dysphagia, and severe cognitive impairment had a G-tube used for meds, water flushes, and enteral nutrition. An LPN administered water, meds, and formula through the tube without checking placement or residual first, and the resident's care plan and MD orders did not include instructions to verify tube placement before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Feeding Care Not Provided as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a GT, dysphagia, Parkinson's disease, and failure to thrive was observed lying flat in bed while receiving enteral feeding and water via pump, despite orders and care plan directions to keep the HOB elevated during feeding. The water bag connected to the pump was also not labeled with the resident's name, date, and time, and an LPN confirmed both the unlabeled bag and the resident's flat positioning during the feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Tube Feeding Not Dated or Timed
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, severe cognitive impairment, and dependence on staff for ADLs received nocturnal Jevity 1.5 via feeding tube, but the bottle was not dated or timed when opened and the tubing was undated. During observation, the feeding was running on a pump while the resident rested in bed with the HOB elevated, and an LPN and the DON confirmed the dating and timing were missing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Enteral Feeding Not Administered as Ordered
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident who depended on PEG tube feeding was ordered Jevity 1.5 at 60 mL/hr for 22 hours daily with free-water flushes, but was observed disconnected from the feeding with the pump turned off and about 1,300 mL of formula still hanging at the bedside. An LPN confirmed she had not connected the feeding and said she forgot to do so, and the DON later confirmed the enteral feeding had not been connected as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Feeding Tube Pump Left Paused and Alarming
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with dysphagia, protein-calorie malnutrition, and dementia had a GT feeding ordered to run 20 hours daily via pump. During observation, the pump was found inactive, paused, and alarming with feeding still remaining in the bottle, and an LVN said she was unaware of the alarm or why the pump was paused. The DON stated tube feedings may be paused for care or meds but should be restarted as soon as possible so the resident receives the full ordered dose.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across New York

Get a heads-up on the newest immediate-jeopardy (J–L) citations in New York — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.