F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
D

Failure to Assess Resident's Change in Condition Leads to Hospitalization

Wellbrooke Of WabashWabash, Indiana Survey Completed on 12-06-2024

Summary

The facility failed to ensure that a resident with a change in condition was properly assessed prior to hospitalization. Resident 51, who had been admitted with diagnoses including a displaced intertrochanteric fracture, type 2 diabetes mellitus with diabetic chronic kidney disease, and anxiety disorder, experienced a significant change in condition. The resident became incoherent and was later hospitalized for hypoglycemia. Despite having a care plan in place to monitor for adverse effects of hypoglycemic medications, the facility did not perform a blood sugar test during the change in condition. On the evening of the incident, the resident was found to be unable to communicate her needs and exhibited symptoms such as staring into space, pinpoint slow reactive pupils, and involuntary twitching. The resident was sent to the hospital where a blood sugar level of 29 mg/dL was recorded, indicating severe hypoglycemia. The facility's clinical records lacked documentation of any blood sugar tests conducted during this period, which was a critical oversight given the resident's diabetic condition and the symptoms presented. Interviews with facility staff revealed that there was a lack of awareness and action regarding the resident's unstable diabetes. LPN 4, who attended to the resident, did not consider checking the resident's blood sugar despite the evident symptoms. The Director of Nursing indicated that a blood sugar test should have been conducted with the change in condition. The facility's policy on hyper/hypoglycemia management was not followed, as it required blood glucose monitoring when signs of hypoglycemia were present.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0658 citations
Failure to Follow Professional Standards for Ophthalmic Medication Administration
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with dry eye syndrome and degenerative eye disease had orders for cyclosporine ophthalmic emulsion and Refresh Tears, both scheduled at the same time. Medication records and direct observation showed a TMA instilled cyclosporine drops in both eyes and immediately followed with Refresh Tears in both eyes without waiting between medications. This practice conflicted with referenced professional guidance recommending several minutes between multiple eye drops and with the medical provider’s recommendation to wait fifteen minutes between the two ophthalmic medications. No facility policy on ophthalmic medication administration was provided when requested.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsubstantiated Schizoaffective Disorder Diagnosis and Antipsychotic Use
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with Alzheimer’s disease and depression exhibited intermittent delusional statements, refusals of medications and care, and occasional yelling or suspiciousness toward staff over several months. Nursing notes documented these behaviors but did not show a comprehensive psychiatric assessment or evidence of a sustained major mood episode. A psychiatric NP subsequently added diagnoses of schizoaffective disorder, borderline personality disorder, and delusions, and ordered Seroquel, despite no prior history of schizoaffective disorder and no detailed evaluation in the record to support the new diagnosis. The resident’s representative reported no known mental health history or hospitalizations and was unaware of the schizoaffective disorder diagnosis, and the DON indicated there was no specific facility policy for schizoaffective disorder.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error from Failure to Verify Resident Identity Before Opioid Administration
G
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A nurse failed to follow professional standards and facility policy for medication administration by not properly verifying resident identity before giving scheduled medications. Two severely cognitively impaired roommates were involved; one had orders for oral morphine and levothyroxine, while the other did not. The RN called out one roommate’s name, but when the other responded, the RN proceeded to administer the morphine and levothyroxine without confirming identity using required methods such as the MAR photo or the 5 Rights of Medication Administration. The wrong resident subsequently developed hypotension and profound bradycardia, was sent to the ED, treated with naloxone for opioid poisoning, and diagnosed with accidental opioid poisoning.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Clarify Oral Medication Orders for NPO Resident
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

The facility failed to meet professional standards of practice when staff did not clarify physician orders for oral medications for a resident who was documented as NPO with dysphagia, esophageal disease, and a gastrostomy. Despite the care plan indicating nothing by mouth, orders for prednisone and magnesium glycinate specified administration by mouth, and nursing staff did not verify or correct these routes before implementation, as required by professional nursing standards.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Allergic Resident Prescribed Contraindicated Antibiotic
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with a documented Doxycycline allergy, noted in both a hospital after-care summary and the EMR allergy banner, was prescribed Doxycycline 100 mg BID for seven days after testing positive for an infectious disease. An RN texted the physician about the test result without the EMR open and entered the Doxycycline order, reporting no recall of an allergy alert. The physician, who did not have EMR access and relied on nursing staff to report allergies, was unaware of the allergy. A Guardian later identified the contraindicated order while reviewing the MAR. The DON stated nurses are expected to have the EMR open when contacting physicians, and the Administrator acknowledged that the physician ordered a medication to which the resident was allergic and that the nurse did not inform him of the allergy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Implement Wound Consultant’s Recommendation for Wound Vac Settings
D
F0658 F658: Ensure services provided by the nursing facility meet professional standards of quality.
Short Summary

A resident with a stage 4 right hip pressure ulcer had physician orders for wound vac therapy at 120 mmHg suction, with specific cleaning and dressing change instructions. A wound consultant later recommended increasing the wound vac suction to 150 mmHg, but this change was never incorporated into the physician’s orders or the Treatment Administration Record. As confirmed by the DON, the consultant’s recommendations were not updated in the clinical record, resulting in the resident continuing on the original wound vac settings contrary to the consultant’s recommendation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙