F0880 F880: Provide and implement an infection prevention and control program.
E

Infection Control Deficiencies in PPE Use and Equipment Maintenance

Beachside Post AcuteTorrance, California Survey Completed on 11-01-2024

Summary

The facility failed to implement proper infection control measures, as evidenced by several observations and interviews. In the case of Resident 260, who was on Enhanced Barrier Precautions (EBP) due to a gastrostomy and an unstageable pressure ulcer, a visitor was observed not wearing the required Personal Protective Equipment (PPE) while interacting with the resident. Licensed Vocational Nurses (LVN) 2 and 3, who attended to Resident 260, did not instruct the visitor to wear PPE and were observed doffing their PPE incorrectly, potentially leading to self-contamination. The facility's policy and CDC guidelines were not followed, as gloves were not removed first, which is crucial to prevent the spread of infection. In another instance, Resident 8, who was also on EBP due to a gastrostomy and stage 3 pressure ulcer, received care from LVN 1, LVN 4, and CNA 1, none of whom wore the appropriate PPE. LVN 1 and CNA 1 entered the room and provided care without donning any PPE, while LVN 4 only wore gloves. This lack of adherence to PPE protocols during high-contact care activities increased the risk of cross-contamination and infection spread among residents and staff. Additionally, the facility failed to maintain the integrity of padded side rails on the beds of four residents, which were covered with duct tape that was cracked and peeling, exposing the foam underneath. This compromised the ability to properly disinfect the side rails, as the foam is a porous material that cannot be sanitized effectively. The maintenance supervisor acknowledged the issue, stating that the duct tape was used as a temporary measure, but it was not recommended by the bed manufacturer. The housekeeping supervisor confirmed that the exposed foam posed a risk for bacterial growth, as the disinfectant used was only effective on hard, non-porous surfaces.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0880 citations
Infection Control Practices Not Consistently Implemented for Resident Evaluated for C. difficile
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident being evaluated for C. difficile was not consistently managed under the correct contact-enteric precautions. Staff gave care with incomplete understanding of the precautions, the room signage did not clearly identify the needed disinfectant or contact time, bleach wipes were not always available, and staff were observed missing hand hygiene and handling items under PPE during care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use EBP PPE During Wound Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Failure to Use EBP PPE During Wound Care: A resident with a wound and severely impaired cognition was receiving ordered wound care when the DON and ADON entered the room, washed hands, and donned gloves but did not wear gowns before starting care. EBP signage and PPE were present at the bedside, and both leaders later stated they forgot to put on gowns even though the resident was on EBP for an open wound and the facility policy required gown and glove use for wound care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Enhanced Barrier Precautions and Hand Hygiene During Resident Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Staff failed to consistently follow EBP and hand hygiene for two residents who required high-contact care. One resident with an indwelling catheter and cognitive impairment did not have EBP followed during transfers, clothing removal, and pericare, and another resident with a suprapubic catheter and multiple pressure ulcers had staff wear PPE incorrectly, remove PPE in the room without hand hygiene, and continue care after emptying the catheter bag without changing gloves or cleaning hands. Interviews confirmed staff were expected to use gowns, gloves, and hand hygiene for these tasks.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Use Required PPE for Resident on Contact Precautions
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A resident on Contact Precautions for active C. difficile infection was not consistently protected by required PPE. Although signage outside the room directed all entrants to wear a gown and gloves, an RN entered the room with medications without either item and touched the bedside table and door surface. The resident stated staff did not always wear gowns, and the DON confirmed staff were expected to wear a gown and gloves when entering the room while precautions were in place.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Lapses During Incontinence and Ostomy Care
E
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

A facility failed to maintain infection control during care for two residents. During incontinence care, a CNA removed gloves and applied clean gloves without hand hygiene before placing a clean brief on a resident who was dependent for toileting hygiene and always incontinent. During ostomy care, an LVN handled a resident’s colostomy, wiped stool from the stoma, and continued care without removing soiled gloves, sanitizing hands, or putting on clean gloves. The DON stated staff were expected to perform hand hygiene between glove changes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Infection Control Failures During Incontinent Care
D
F0880 F880: Provide and implement an infection prevention and control program.
Short Summary

Infection Control Failures During Incontinent Care: Two residents were observed receiving incontinent care with multiple infection control lapses. A CNA did not perform hand hygiene between glove changes or after glove removal while caring for one resident, and another CNA did not wash hands before care, changed nothing between dirty and clean tasks, touched clean items with dirty gloves, placed soiled linens on the floor, and handled dirty linens with bare hands after glove removal. The DON stated hand hygiene, glove changes, and proper handling of soiled linens were required, and facility policies reflected those practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.