F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
D

Failure in Kitchen Staff Competency for Manual Warewashing

Peninsula Post-acuteBurlingame, California Survey Completed on 10-18-2024

Summary

The facility failed to ensure the competency of one kitchen staff member in manual warewashing using the three-compartment sink, which is essential for cleaning and sanitizing utensils and food-contact surfaces. This deficiency was identified during an observation and interview with the Dietary Aide (DA) and the Dietary Supervisor (DS). The DA incorrectly described the procedure for using the three-compartment sink, omitting the crucial step of sanitizing. According to the facility's policy, the first compartment is for washing with detergent and hot water, the second for rinsing with clean hot water, and the third for sanitizing with a solution. However, the DA stated that the first sink was for scraping food, the second for washing with soap, and the third for rinsing in plain water, without mentioning the sanitizing step. The DS confirmed that the procedure should include scraping, washing, rinsing, and sanitizing, with the first sink for washing, the second for rinsing, and the third for sanitizing. The failure to ensure the DA's competency in this procedure had the potential to result in contamination of food, utensils, and equipment, which could lead to illness caused by pathogens. This deficiency was noted as affecting one of the eight kitchen staff members responsible for manual warewashing when the dish machine is not operational.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0802 citations
Dish Machine Chlorine Test Strips Misread by Dietary Staff
D
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Dish Machine Chlorine Test Strips Misread by Dietary Staff: Dietary staff were observed and interviewed while checking chlorine in the dish machine, and both DAs stated they estimated strip readings instead of interpreting the color chart correctly. The Dish Machine Temperature Log showed several recorded ppm values that did not match the chart, and the DS stated staff had been told to read the strips by estimating. The facility P&P required chlorine to read 50-100 ppm on the dish surface in the final rinse.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Food Service Staff Lacked Current Food Handler Certification
D
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Food service staff lacked current food handler certification when two kitchen staff were observed preparing lunch meals and record review showed one expired certificate and one missing certificate. Interviews confirmed one staff member did not have a current certificate and another learned her certificate had expired, while the MTD was assisting in the kitchen after the prior dietary manager was terminated.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Dishwasher Sanitization Temperatures Not Understood by Kitchen Staff
F
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Dishwasher Sanitization Temperatures Not Understood by Kitchen Staff: Kitchen staff did not know the required high-temp dishmachine settings for sanitization. During observation, the wash cycle reached 150°F and the rinse cycle reached 171°F, while the staff member operating the machine stated those were normal and sufficient to sanitize dishes. The DM and RD later stated the wash cycle needed to reach 160°F and the rinse cycle at least 180°F, and the facility policy listed the same temperatures.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Food Handler Certificate for Dietary Aide
D
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Expired Food Handler Certificate for Dietary Aide: The facility failed to ensure a dietary aide maintained a current Food Handler Certificate. Record review showed the aide’s certificate had expired, and interviews with the DM, DON, and Administrator confirmed they were responsible for tracking staff certification status but had not noticed the expiration. The aide stated she did not realize the certificate had expired, and the facility policy required all employees who handle, prepare, or serve food to be trained in safe food handling and preventing foodborne illness.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Dietary staffing shortages led to repeated dining room closures and service issues
F
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Repeated dietary staffing shortages resulted in frequent dining room closures, missed meal service in the dining room, and resident complaints about food quality, incorrect menus, and the kitchen running out of items. Staff reported that cooks and dietary aides repeatedly called off or were not scheduled, several dietary workers were not replaced, and the Administrator said staffing decisions were made by a third-party vendor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Insufficient Dietary Staffing Caused Delayed Meal Service
E
F0802 F802: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
Short Summary

Insufficient dietary staffing delayed meal service and disrupted resident care. Dietary staff were still on the tray line during breakfast service, the last breakfast cart left the kitchen late, and lunch tray line preparation was repeatedly delayed with trays not ready until well after the scheduled time. Residents on the unit were still eating breakfast late in the morning, lunch trays were not delivered to the 400 hall until mid-afternoon, and CNAs reported meals were often so late that it affected when they could provide showers and other care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙