F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
D

Inadequate Catheter Care and Missed Urology Follow-Up

Seneca Health Care CenterWest Seneca, New York Survey Completed on 11-08-2024

Summary

The facility failed to provide appropriate care for residents with indwelling catheters, leading to deficiencies in managing catheters and preventing urinary tract infections for two residents. Resident #53, who had severe sepsis, urinary tract infection, and bladder outlet obstruction, did not receive a follow-up urology appointment after a cystoscopy. The appointment was rescheduled without proper documentation or communication, resulting in a missed follow-up. Additionally, Resident #53's catheter care was inadequate, as the foley leg bag was not used during daytime hours as planned, and the catheter tubing was observed lying on the floor, posing an infection risk. Resident #27, with a history of urinary tract infections and moderate cognitive impairment, also experienced inadequate catheter care. Observations revealed that the foley catheter drainage bag was lying on the floor and later positioned above the bladder level, both of which are improper practices that can lead to infections. The staff responsible for Resident #27's care were unaware of these issues, indicating a lack of adherence to proper catheter management protocols. Interviews with facility staff, including the Director of Nursing and the Assistant Director of Nursing/Infection Preventionist, confirmed that the catheter care provided to both residents did not meet the facility's standards. The staff acknowledged the risks associated with improper catheter placement and the potential for infection, yet failed to ensure that the necessary precautions were taken to prevent such occurrences.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Improper Securing of Suprapubic Catheter Tubing
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with Alzheimer’s disease, CKD, BPH, obstructive uropathy, and urinary retention had a suprapubic catheter that staff repeatedly secured incorrectly. During catheter care, two nurses cleaned the abdominal insertion site but attached the Stat-lock to the resident’s thigh, anchoring the tubing to the leg instead of the abdomen. Nursing leadership stated they expected leg anchoring and noted the catheter policy did not specify Stat-lock placement, even though the facility’s suprapubic catheter competency checklist explicitly directed that the tubing be secured to the abdomen.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Catheter Care Standards and Care Plan
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with Alzheimer’s disease, CKD, BPH, obstructive uropathy, and a neurogenic bladder had an indwelling catheter ordered with a Stat-lock securement device and shift-by-shift monitoring of urine output. Surveyors observed the resident self-propelling a wheelchair while leaving a stream of apparent urine on the floor and later noted the resident sitting with a very full catheter bag hanging under the wheelchair. During observed catheter care, CNAs emptied the bag and checked the insertion site but did not use a Stat-lock, and one CNA reported they usually emptied catheter bags only at the end of their shift and did not apply a Stat-lock because the resident removed it. A nurse confirmed that all catheterized residents should have a Stat-lock and that supplies were available, while an administrative nurse stated expectations that Stat-lock use follow the care plan and that there was no written catheter care policy, with the facility instead relying on standards of practice.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Obtain Physician Orders for Indwelling Urinary Catheter After Readmission
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a history of obstructive uropathy and a suprapubic catheter returned from a hospital stay with the catheter still in place, but the facility did not obtain new physician orders for catheter care, catheter size, change frequency, or irrigation after readmission. Previous orders for catheter care and monthly catheter changes using a specified 18 Fr/10 cc catheter had expired prior to the hospital transfer. Despite multiple observations of the resident with a leg bag and confirmation by staff that the catheter remained in use, no corresponding catheter-related orders were in the current physician or readmission orders, and the DON acknowledged that appropriate catheter orders had not been obtained.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Timely Incontinence Care and Proper Call Light Response
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with severe cognitive impairment, bowel and bladder incontinence, and identified risks for falls and impaired skin integrity requested a brief change via call light. An activity assistant answered, turned off the call light, and left without providing care or notifying nursing staff. For over 30 minutes no staff returned, and when a CNA later entered only to deliver a meal tray, the resident was found with a soiled brief, visibly soiled linens, and dried stool on the buttocks, appearing distressed and repeatedly calling out about her diaper. The CNA, who had not been informed of the earlier request, then provided incontinence care. These events occurred despite facility policies requiring timely incontinence care and that call lights remain on until the resident’s request is met.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Monitor and Manage Indwelling Catheter Leading to Worsening Penile Injury and Urine Leakage
G
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with severe cognitive impairment, neurogenic bladder, and an indwelling Foley catheter experienced a progressive slit on the penis and urine leakage into an incontinent brief due to inadequate catheter monitoring and care. Orders and the care plan required every-shift assessment of the catheter site for redness, irritation, urethral erosion, leakage, and urine characteristics, but nursing documentation showed no reported issues while the penile slit enlarged from a small, non-bleeding area to a beefy red, bleeding wound extending from the meatus down the shaft. During observed care, the resident’s brief was saturated with urine, dressings were wet and non-adherent, and the catheter tubing contained sediment with cloudy, sediment-filled urine in the bag. Staff interviews revealed that some staff had known about the slit for weeks, the assigned nurse had not assessed the penis or recognized leakage despite making rounds, and the NP had not been informed of the worsening condition or catheter leakage, demonstrating failures to monitor, recognize, and report catheter-related complications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Foley Catheter Management and Infection Control Practices
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with quadriplegia, chronic kidney disease, and a history of UTIs had an indwelling Foley catheter and a care plan directing staff to keep the drainage bag below bladder level, provide catheter care each shift, and monitor and document output. Surveyors repeatedly observed the urine drainage bag, containing a large volume of amber urine with white mucus, lying directly on the floor while an LPN entered the room to administer medications and feed the resident without correcting the bag’s position. Later, despite posted enhanced barrier precautions and available supplies, a CNA wearing only gloves placed a urinal directly on the floor, emptied approximately 1,800 mL from the drainage bag while intermittently placing both the bag and urinal on the floor, left the spigot open on the floor during the process, and failed to clean the spigot tip with alcohol, contrary to facility policy and expected infection control practices.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙