F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Error Rate Exceeds Acceptable Threshold

Majestic Care Of South BendSouth Bend, Indiana Survey Completed on 10-04-2024

Summary

The facility failed to maintain a medication error rate below 5 percent, as evidenced by observations during a medication pass involving two residents. For Resident 28, the medication Fluticasone Propionate was not available for administration, and the nurse indicated she would contact the pharmacy to obtain it. This resident had diagnoses including chronic pain syndrome and allergies, with a physician's order for Fluticasone Propionate dated several months prior. The absence of this medication during the scheduled administration contributed to the facility's medication error rate. For Resident 35, the nurse found two inhalers in the medication drawer without opened dates and decided not to administer the medication, opting instead to notify the pharmacy for a new one. This resident had a diagnosis of chronic obstructive pulmonary disease, with a physician's order for Albuterol Sulfate. The Director of Nursing later indicated that Albuterol was available in the emergency kit, and if not, the nurse should notify the pharmacy. The facility's policy on medication administration, which includes procedures for obtaining medications not readily available, was provided by the DON. These incidents resulted in a medication error rate of 8 percent, exceeding the acceptable threshold.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Medication Error Rate Exceeded Due to Unprimed Insulin Pen Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication error rate exceeded the 5% threshold when an RN administered two insulin doses to a resident with DM without priming the Lantus and NovoLog pens before each injection. Surveyors observed the RN give the ordered subcutaneous doses without completing the manufacturer-required safety test, and the RN stated she believed priming was only needed before first use. The DON and consultant pharmacist confirmed the pens should be primed before each dose.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate when an MA gave late doses, administered a BP medication outside ordered parameters, and gave an incorrect dose of a PPI. One resident with metabolic encephalopathy, cognitive communication deficit, and HTN received Metoprolol late, and another resident with seizures, stroke, GERD, and HTN received Levetiracetam late, Lisinopril despite BP below the hold parameter, and Pantoprazole at 20 mg instead of the ordered 30 mg.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded 5 Percent
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Error Rate Exceeded 5 Percent: The facility had a 7.41% medication error rate after two errors were identified. A resident ordered acetaminophen and Refresh Tears received acetaminophen and artificial tears instead of the ordered eye drops, and the CMA reported giving the meds with the morning pass and not notifying an LN that they were late. The pharmacist confirmed the eye drops and artificial tears were not the same medication, and the regional RN stated meds should be given within one hour before or after the scheduled time.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Error Rate Exceeded
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Administration Error Rate Exceeded: The facility had a 7% medication error rate during observation. An LPN gave a resident sucralfate as a tablet with water instead of as a slurry 1 hour before meals, and an RN administered only one Senna Plus tablet instead of two while lidocaine patches were unavailable and on order. The resident involved in the sucralfate error had anxiety, depression, muscle weakness, and moderate cognitive impairment.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate when surveyors observed 4 errors in 27 opportunities. An LPN gave one resident's Keppra, Lexapro, and metformin late despite orders for 9 AM administration, and another LPN gave a resident's metoprolol without breakfast even though the order required it with breakfast. The DON confirmed the facility policy required medications to be given within one hour of the ordered time, and staff acknowledged the orders were not followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Late Administration of Scheduled Morning Medications
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Late Administration of Scheduled Morning Medications: Surveyors found an 11.11% med error rate after an MA gave three residents their 6:30 a.m. meds well after the scheduled time. One resident with dementia and DM received metformin late and initially refused it, while two other residents with GERD or indigestion-related orders received Protonix or omeprazole late while one was sleeping and another was resting in bed. Interviews with the MA, RN, and DON confirmed late administration was considered a med error and should be reported to nursing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Indiana

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Indiana — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.