F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
D

Improper Use of Hoyer Lift Leads to Resident Injury

Healthwin Health & RehabilitationSouth Bend, Indiana Survey Completed on 09-25-2024

Summary

The facility failed to ensure the safe use of a Hoyer Lift for a resident, identified as Resident D, who was at high risk for falls due to multiple medical conditions including a non-traumatic brain injury, insulin-dependent diabetes, seizure disorder, and aphasia. The resident was non-verbal and fully dependent on staff for transfers, as indicated in her care plan, which required the use of a mechanical lift with two staff members. During a transfer from a recliner to a bed, the resident slipped from the Hoyer sling, and although caught by a CNA, was lowered to the floor. The incident occurred when two CNAs were conducting the transfer. CNA 3 attached the sling to the Hoyer lift while CNA 2 operated the controls. Despite the sling being attached, the resident began to slip out of it during the transfer. CNA 3 managed to catch the resident, preventing her from hitting the floor, but the resident was still lowered to the ground. The CNAs reported that the resident did not hit her head or limbs on any objects, and the sling remained attached to the lift. However, there was uncertainty about whether the sling was properly positioned or secured, as CNA 2 assumed the sling was crossed from previous use. Following the incident, the resident was assessed and initially showed no signs of pain or injury. However, subsequent medical evaluations revealed fractures in the resident's left tibia, fibula, and left thumb, as well as bone demineralization. The facility's policies on lift use and fall management were reviewed, but the investigation did not clarify how the resident slipped from the sling if it was properly attached. The incident was self-reported by the facility after the fractures were discovered during a hospital evaluation.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Ensure Effective Fall Alarms and Supervision
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to ensure effective fall alarms and supervision: two residents had Smart Caregiver monitoring devices set to LOW volume, and one resident's bed alarm did not alert staff before the resident was found on the floor after an unwitnessed fall. One resident had dementia, osteoporosis, prior TIA, and cognitive impairment and was fully dependent on staff, while staff also found that a second resident's bed and recliner alarms did not activate properly during testing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safety of Perimeter Mattresses
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to assess the safety of perimeter mattresses for two residents. Both residents had severely impaired cognition and significant mobility limitations, and both care plans included use of a perimeter mattress to define the edges of the bed. However, their Mobility, Physical Device, and Fall Risk assessments lacked documentation of a perimeter/defined edge mattress assessment. Staff interviews showed inconsistent understanding of the required order, IDT review, engineering review, and safety assessment before use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Mechanical Lift Transfers
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Improper Mechanical Lift Transfers: A resident with dementia, spinal cord dysfunction, and dependence for transfers was supposed to be moved with a full-body mechanical lift and two staff members, but a TMA stated she transferred the resident alone. The resident reported that staff sometimes used only one person for lift transfers because of staffing shortages, while other staff and the DON stated this was unsafe and against policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe Wheelchair Fit and Incomplete Post-Fall Monitoring
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Two residents were involved in accident-hazard deficiencies. One resident with cancer, PVD, and Alzheimer’s disease was observed in a wheelchair with feet extending past short footrests, with the lower legs resting against the hard footrests despite a care plan entry for padding. Another resident with dementia and a hx of falls had an unwitnessed fall, but ordered orthostatic BP monitoring was not completed accurately and staff reported no post-fall PT referral was received.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to assess electric wheelchair use and update fall interventions
G
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident was given a new electric wheelchair without a prior therapy assessment and could not stop the chair, causing it to strike a bed frame and resulting in a leg laceration, tibia/fibula fractures, and a syncopal episode from blood loss. Another resident with cognitive impairment and high fall risk continued to self-transfer and fall, but the care plan was not updated with new fall interventions after repeated incidents.

Inspection fine: $17,665
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsafe One-Person Use of Mechanical Lift
E
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A CNA used a Hoyer lift alone to weigh one resident, and another CNA was observed using a Hoyer lift alone to weigh a second resident. One resident’s care plan called for a 2-assist Hoyer lift, and the facility’s lift competency checklist and policy both required two caregivers for mechanical lift use; the DON and Director of Therapy also stated that two staff members are always required.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Indiana

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Indiana — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙