F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
D

Deficiencies in Enteral Feeding and Medication Administration

Parkway Health And Rehabilitation CenterMemphis, Tennessee Survey Completed on 08-21-2024

Summary

The facility failed to provide appropriate care and services for residents with enteral feedings, as evidenced by multiple deficiencies in the administration of medications and maintenance of feeding tubes. For Resident #8, the facility did not adhere to its own policies or physician orders. During a medication administration observation, an LPN crushed and mixed multiple medications together, contrary to the policy that requires each medication to be administered separately to avoid interactions. Additionally, the LPN used a plunger to push the medications and water flushes through the PEG tube, rather than allowing them to flow by gravity, and did not flush the tube with the prescribed 60 cc of water before and after medication administration. Similarly, for Resident #10, the facility failed to follow proper procedures for medication administration through a PEG tube. An LPN did not check the residual of the PEG tube before administering medication, as required. The LPN also used a plunger to administer the medication and water flushes, and did not use the prescribed amount of water for flushing the tube. Furthermore, the LPN did not ensure that the syringe and plunger were properly dried before storage, which is against the facility's policy. For Resident #90, the facility did not ensure that enteral feeding and flush solutions were properly labeled. Observations revealed that the Jevity container and water flush solutions lacked labels indicating the rate of administration and the time they were started. This lack of labeling was confirmed by the DON, who acknowledged that the feeding and flush solutions should be labeled with the resident's name, flow rate, and room number. These deficiencies indicate a failure to comply with established protocols for the safe and effective administration of enteral feedings and medications.

Penalty

Fine: $103,98043 days payment denial
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations in Ohio
Failure to Provide Ordered G-Tube Care and Dressing
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with multiple complex conditions, including dementia, dysphagia, and dependence on G-tube feeding, had physician orders for continuous tube feeding, scheduled water flushes, and daily cleansing of the G-tube site with application of a sponge dressing. During observation, an LPN found the G-tube site without the ordered dressing and cleaned brown/red dried drainage from the insertion area, acknowledging that a dressing should have been in place. The DON later reported there was no formal facility policy or procedure for G-tube care and maintenance, even though additional residents also had G-tubes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Tube Feeding and PEG Flushes
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with multiple serious conditions, including anoxic brain damage, respiratory failure, dysphagia, and gastrostomy status, had physician orders for Jevity 1.5 bolus tube feedings every four hours and PEG flushes with 60 mL water before and after each feeding and every four hours. EMR and MAR review showed that on one day the resident did not receive the ordered bolus feedings or PEG flushes at two scheduled administration times, contrary to physician orders, the facility’s medication administration policy, and the resident’s right to adequate and appropriate medical and nursing care.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Tube Feeding Due to Unresolved Pump Clog
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with severe cognitive impairment and a PEG tube did not receive the prescribed amount of enteral nutrition when the tube feeding pump repeatedly indicated a clog and was not infusing. The LPN on duty had not yet checked on the resident and was unaware of the issue, resulting in the resident missing the ordered nutrition.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Prevent Mold Formation in Feeding Tube
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with multiple medical conditions and a PEG tube developed mold within the feeding tube due to the facility's failure to provide proper routine care and monitoring as ordered. Staff did not recognize or report the discoloration in the tube, and the issue was only addressed after the resident was sent to the hospital for evaluation and tube replacement.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Implement Tube Feeding Orders Upon Readmission
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with multiple medical conditions, including malnutrition, was readmitted from the hospital with an order for Nutren 2.0 tube feeding. The facility did not enter the tube feeding order into the medical record or provide the prescribed nutrition, as the ordered formula was not available and no alternative was used, despite facility policy allowing for basic formulary products until specialized products could be delivered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Enteral Nutrition Due to Formula Substitution
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with a PEG tube and multiple medical conditions was admitted with a physician's order for nocturnal Jevity 1.5 tube feeding. Due to the facility being out of Jevity 1.5, an LPN substituted Jevity 1.2 two days after admission, resulting in the resident not receiving the ordered formula for two nights.

Fine: $26,685
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

65.1% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 55 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙