F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Administration Errors and Missed Dose

North Las Vegas Care CenterNorth Las Vegas, Nevada Survey Completed on 09-11-2024

Summary

The facility failed to maintain a medication error rate below five percent, with a reported rate of 9.38% during a medication administration pass. This deficiency involved two residents, one of whom was unsampled. The errors were primarily related to the administration of Metformin, an antidiabetic medication, which was not given in accordance with the physician's orders. The orders specified that Metformin should be administered with meals to ensure proper absorption and efficacy. However, the medication was given more than an hour after breakfast, which was outside the prescribed timeframe. For Resident 58, the LPN administered Metformin at 8:21 AM, despite the breakfast being finished about an hour earlier. Similarly, for Resident 61, Metformin was administered at 8:37 AM, also more than an hour after breakfast. The LPN admitted to combining the 7:00 AM and 8:00 AM medication passes to save time, which led to the late administration of Metformin. The Unit Manager and DON confirmed that the medication was not administered as per the physician's orders, and the facility's policy required medications to be given within one hour of the scheduled time. Additionally, there was a missed dose of Risperdal for Resident 61 due to the medication being unavailable. The LPN did not reorder the medication in time and failed to notify the physician about the missed dose. The Unit Manager indicated that the LPN should have checked the medication dispensing system for an alternative supply or contacted the physician for guidance. The DON confirmed that the missed dose was not handled properly, as the facility's policy required immediate action to obtain unavailable medications and to report missed doses to the physician.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations in Ohio
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Result in Exceeding 5% Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed two medication administration errors that caused the facility’s medication error rate to exceed 5%. In one case, an LPN administered insulin using a pen device to a resident with diabetes without priming the pen as required by the manufacturer’s instructions. In another case, an LPN measured a resident’s ordered 17 g dose of MiraLAX by filling the product cap only partway instead of to the top rim as specified on the container, then administered the inaccurately measured dose. These actions resulted in a calculated medication error rate of 7.14% during the survey.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Prime Insulin Pens Resulting in Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed an LPN administering insulin to a resident with type 2 DM and daily insulin orders without priming either the lispro or Lantus insulin pens before dialing and giving the doses, contrary to manufacturer instructions requiring priming before each injection. The resident’s blood sugar was elevated, and the LPN confirmed the pens were not primed. This contributed to 2 errors in 25 opportunities, resulting in a medication error rate above the 5% threshold.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Omission Errors Resulting in Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility exceeded the acceptable medication error rate when, during a morning med pass, an RN was unable to administer an ordered dose of Synthroid to a resident with diabetes, hypothyroidism, and hypertension because it was not available in the med cart or emergency box, and also failed to remove a scheduled dose of glipizide from the medication card until prompted by the surveyor. These two omission errors, identified during observation and confirmed in staff interviews and record review, resulted in a 7% medication error rate for 28 observed medication opportunities.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Improper Ophthalmic Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found the facility exceeded the acceptable medication error rate when an LPN administered multiple ophthalmic medications to a resident with complex medical conditions and moderate cognitive impairment. The LPN instilled Atropine and Prednisolone, which were ordered for only one eye, into both eyes, and also gave Brimonidine and Brinzolamide in both eyes without clarifying an incomplete order for Brinzolamide. The LPN did not observe the required time intervals between different eye drops as specified by manufacturer instructions and facility policy, contributing to four medication errors during a single medication pass.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded 5% During Insulin Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility’s medication error rate exceeded 5% when two residents with type 2 DM did not receive insulin as ordered. For one resident, an LPN administered eye drops and oral medications but held the ordered morning Lantus dose without resident refusal, provider notification, or any order parameters to hold the insulin, despite facility policy requiring prescriber contact if a dose is believed inappropriate. For another resident, an RN administered Lantus using a pen device without performing the required priming/safety test steps outlined in the manufacturer’s instructions, instead only checking for air bubbles before injection. These two insulin-related errors, out of 34 observed opportunities, resulted in a 5.8% medication error rate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

65.1% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 55 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙