F0641 F641: Ensure each resident receives an accurate assessment.
D

Inaccurate Assessment of Resident's Hearing Needs

Jewish Home & Rehab Center D/p SnfSan Francisco, California Survey Completed on 08-28-2024

Summary

The facility failed to accurately assess the hearing needs of a resident, identified as Resident 356, who was admitted with a diagnosis of a displaced fracture of the medial condyle of the right femur. Upon admission, the resident was noted to use hearing aids, yet the Minimum Data Set (MDS) assessment inaccurately recorded that the resident did not use hearing aids. This discrepancy was highlighted during a review of the resident's care plan, which indicated a communication problem related to a hearing deficit, with interventions including the application of bilateral hearing aids while awake. Observations and interviews revealed that the resident had been using only one hearing aid due to the right-sided hearing aid being broken, an issue that had persisted for about ten days. The resident communicated this problem by pointing to her left ear and explaining the situation to staff. However, RN 3, during an interview, was unaware of the resident's use of only one hearing aid. MDS Nurse 1 acknowledged the inaccuracy in the MDS assessment, admitting that it should have reflected the resident's use of hearing aids, thus indicating a failure in accurately assessing and documenting the resident's hearing needs.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0641 citations
Inaccurate MDS Assessments for Medication Use and Diagnoses
E
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for several residents. One resident’s admission MDS listed insulin injections even though she received liraglutide, while two other residents’ MDSs omitted antidepressant, opioid, and scheduled pain medication use despite active orders and MAR documentation. Another resident’s quarterly MDS failed to include respiratory failure as an active dx even though the record, orders, and resident interview confirmed the condition and oxygen use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate Resident Assessments
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate resident assessments were identified for multiple residents when MDS coding did not match the clinical record, observations, or staff statements. One resident was coded as having a restraint-related chair device despite no restraints being observed or ordered, another was coded as not receiving antibiotics despite MAR documentation of mupirocin use, and two other residents had missing or incorrect MDS entries for diagnoses, ROM status, and skin/wound conditions based on admission records, physician notes, wound care documentation, and staff interviews.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Weight Loss and Active Diagnoses
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding affected two residents. One resident had significant weight loss documented in the EHR, but the quarterly MDS did not reflect the loss as required. Another resident with lung cancer and metastatic disease had an admission MDS that omitted active cancer diagnoses from section I. The MDS/LPN acknowledged the missing diagnosis, and the DON stated MDS assessments were expected to be coded accurately.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Assessments for Oxygen Use, Depression, and Range of Motion
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A facility failed to ensure MDS assessments accurately reflected resident status for multiple residents. One resident’s oxygen use was not captured in Section O despite PRN O2 orders and repeated oxygen saturation documentation, another resident’s MDS omitted oxygen use despite progress notes and an O2 order, a third resident’s MDS omitted depression despite a citalopram order, and a fourth resident’s MDS coded no ROM impairment even though PT identified quadriplegia with limitations in all extremities.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Weight Loss Coding
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

A resident’s quarterly MDS incorrectly coded significant weight loss even though his documented weights did not show 5% loss in 1 month or 10% loss in 6 months. The MDS RN said she based the coding on weight fluctuations and medication changes rather than actual loss during the look-back period, and the resident’s care plan continued to reflect significant unplanned weight loss, poor intake, and anxiety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inaccurate MDS Coding for Diabetes Medications
D
F0641 F641: Ensure each resident receives an accurate assessment.
Short Summary

Inaccurate MDS coding was found for two residents whose diabetes meds were non-insulin injectables. One resident with ESRD and diabetes had Ozempic ordered, and another resident with CKD and diabetes had Mounjaro ordered, but both MDS assessments incorrectly coded insulin use and hypoglycemic drug class use. The MDS coordinator acknowledged the coding error but did not update the assessments after learning of the inaccuracy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙