F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
G

Failure to Monitor and Recognize UTI and Sepsis Symptoms

Solano Post AcuteVallejo, California Survey Completed on 07-15-2024

Summary

The facility failed to ensure that staff were adequately trained and aware of the symptoms and risks associated with sepsis and urinary tract infections (UTIs). This deficiency was highlighted by the case of a resident who was hospitalized due to sepsis. The resident, who had intact cognition and required assistance with activities of daily living, was not properly monitored for signs and symptoms of a UTI, despite a physician's order to do so. The lack of monitoring and awareness among staff led to the resident developing severe sepsis, which was confirmed upon hospitalization. Interviews with various licensed staff members revealed a general lack of understanding and vigilance regarding the symptoms of UTIs and the progression to sepsis. Staff members acknowledged that some residents might not present with classic UTI symptoms, yet they failed to monitor residents closely for subtle changes in condition, such as altered mental status or general malaise. The staff's failure to recognize these signs and take appropriate action contributed to the resident's condition worsening to sepsis. The Director of Staff Development confirmed that the resident was transferred to the emergency department due to altered mental status and that no urinalysis was conducted to check for a UTI. The facility's policies on change of condition and UTI management were not effectively implemented, as evidenced by the lack of immediate consultation with a physician and failure to identify and treat the infection in a timely manner. The absence of a provided policy and procedure for sepsis further underscores the facility's deficiency in managing and preventing such critical conditions.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0726 citations in Ohio
Insufficient Qualified Nursing and Respiratory Staff for Ventilator-Dependent Residents
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

The facility failed to ensure adequate RN or RT coverage for two ventilator-dependent residents whose care plans and orders required frequent ventilator checks, trach care, suctioning, HME and circuit changes, and close monitoring of respiratory status. On at least one night shift, only LPNs were on duty with no RN or RT present, despite these residents’ dependence on mechanical ventilation and tracheostomies. The DON acknowledged there was no RN or RT on that shift, believed prior daytime RN presence met requirements, allowed LPNs to perform ventilator care without certification or documented competency, and was unsure whether such care was within LPN scope of practice. Cited literature from the National Library of Medicine noted that mechanical ventilators are complex, require specific training, and are best managed by RTs, with improper management linked to poor outcomes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Ensure Competent IV Therapy Administration by Agency LPN
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A resident with a PICC line for IV cefepime therapy and multiple comorbidities received IV medication from an LPN who attached IV tubing directly to the open end of the PICC line without a needleless connector, after cleaning only the open hub. The LPN stated that PICC lines do not have valves, despite reporting prior IV therapy training. Facility leadership and HR reported they did not maintain competency or training records for agency staff, and one agency only verified licensure while another provided a self-assessment showing the LPN rated IV skills as limited and requiring supervision, even though the facility’s contract assigned responsibility for orientation, education, and competency of agency staff to the facility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Uncertified Staff Member Allowed to Perform CNA Duties
F
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A staff member was hired and worked in the capacity of a CNA for an extended period without ever obtaining CNA certification or being listed on the Nurse Aide Registry. HR records and interviews showed that the individual completed two Nurse Aide Training classes and repeatedly failed the written competency test, yet was still permitted to perform CNA duties and provide direct care to residents. The personnel file contained only training completion certificates and no verification of an active CNA certification or registry check, affecting care provided to all residents in the facility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Train Staff on Mechanical Lift Use and Adherence to Transfer Protocols
E
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A CNA transferred a resident with cognitive and physical impairments using a mechanical lift without a second staff member present and without having received proper training on the equipment, in violation of facility policy requiring two trained staff for such transfers.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Qualified Staff for IV Medication Administration via PICC Line
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

A resident with complex medical needs did not receive prescribed IV vancomycin through a PICC line because no RN was available to administer the medication. The medication was delivered, but scheduled doses were missed due to the absence of qualified staff, despite facility policy requiring timely administration of medications.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unqualified LPNs Removed Midline IV Catheters
D
F0726 F726: Ensure that nurses and nurse aides have the appropriate competencies to care for every resident in a way that maximizes each resident's well being.
Short Summary

Two residents with midline IV catheters for UTI treatment had their catheters removed by an LPN who lacked documented training and was not qualified under state regulations or facility policy to perform this procedure. Staff interviews and record reviews confirmed that the LPN did not have the required competencies, and there was confusion among staff about the scope of LPN practice regarding midline IV removal.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

65.1% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 55 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙