F0770 F770: Provide timely, quality laboratory services/tests to meet the needs of residents.
E

Failure to Obtain Monthly CBCs for Resident on Immunosuppressive Therapy

Autumn Care Of Myrtle GroveWilmington, North Carolina Survey Completed on 07-23-2024

Summary

The facility failed to obtain a monthly complete blood cell count (CBC) for a resident receiving immunosuppressive drug therapy, as ordered by the physician. The resident, who was admitted with diagnoses including rheumatoid arthritis and heart failure, had a physician's order dated 11/27/23 for monthly CBCs. A CBC was collected on 11/30/23, but from 12/31/23 through 07/08/24, there was no documentation or results of the required monthly CBC tests in the resident's electronic medical record. The Nurse Practitioner, who began working at the facility in January 2024, was unaware of the order for monthly CBCs and relied on lab results from the resident's Rheumatologist, which were accessible through the hospital's electronic medical record system. The issue arose because the Unit Manager, who entered the initial order for monthly CBCs, did not complete the necessary requisition form to notify the lab vendor to draw the labs. The facility had recently transitioned to a new electronic medical record system, which included a new process for ordering labs. This process required entering the order into the electronic medical record and then directly into the vendor's website, bypassing the previous method of using a handwritten requisition form. The Director of Nursing confirmed that the new process was in place and that nurses had been educated on it, but was unaware of the specific order for the resident's monthly CBCs.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0770 citations
Failure to Arrange Ordered WBC Lab Draw After ED Return
D
F0770 F770: Provide timely, quality laboratory services/tests to meet the needs of residents.
Short Summary

A resident with severe cognitive impairment, dementia, and chronic lymphocytic leukemia returned from the ED with an order to recheck a WBC the next day, but nursing staff failed to arrange the lab draw. The AVS was reviewed later, the missed order was discovered, and staff stated the charge nurse was responsible for checking post-visit orders and that the lab order had been overlooked.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Missed Ordered Laboratory Testing
J
F0770 F770: Provide timely, quality laboratory services/tests to meet the needs of residents.
Short Summary

Missed Ordered Laboratory Testing: The facility failed to obtain multiple ordered labs for several residents, including PT/INR monitoring for a resident transitioning from Eliquis to Coumadin with a Lovenox bridge, urinalyses for residents with suspected UTI/CAUTI, CBC/CMP testing, anticonvulsant levels, blood cultures, and an ammonia level. One resident developed active bleeding with critically abnormal lab values and died in the facility while bleeding from multiple sites. The record also showed several ordered tests were not found or were not completed as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Wound Culture Not Completed as Ordered
D
F0770 F770: Provide timely, quality laboratory services/tests to meet the needs of residents.
Short Summary

A resident with an abdominal surgical incision and left flank wound had a wound culture ordered after green drainage was noted from the wound vac, along with IV vancomycin and aztreonam. The culture was cancelled because the wrong tube was used, the wound was not re-cultured, and the wound nurse stated she had swabbed the fluid instead of the surgical site and believed the culture had already been completed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Obtain Ordered Laboratory Services
D
F0770 F770: Provide timely, quality laboratory services/tests to meet the needs of residents.
Short Summary

A facility failed to obtain ordered lab services for a resident with HTN, anxiety, and muscle weakness. The record showed a provider ordered a CBC and BMP for monitoring, but documentation did not show the CBC was completed as ordered, and an IP confirmed the failure.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Ordered Laboratory Tests Not Completed
D
F0770 F770: Provide timely, quality laboratory services/tests to meet the needs of residents.
Short Summary

Ordered lab services were not completed for a resident with epilepsy. The resident had physician orders for a phenobarbital level and a TSH level, but neither test was drawn or resulted as ordered. An MDS nurse confirmed the missed labs, and the facility policy required timely lab services when ordered by the MD/NP/PA.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Missed Ordered Lab Collection
D
F0770 F770: Provide timely, quality laboratory services/tests to meet the needs of residents.
Short Summary

A resident's ordered BMP was not collected as directed because the order was not entered into the facility's online system with the correct collection date. An LPN stated the receiving nurse enters lab orders and the evening nurse collects the sample, and the DON confirmed the lab sample was not collected as ordered.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across North Carolina

Get a heads-up on the newest immediate-jeopardy (J–L) citations in North Carolina — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.