F0759 F759: Ensure medication error rates are not 5 percent or greater.
E

Medication Administration Errors

Pomona Vista Care CenterPomona, California Survey Completed on 04-18-2024

Summary

The facility failed to ensure that the medication error rate was less than 5% during medication administration for two of five sampled residents. The medication error rate was found to be 11.11% due to three medication errors out of 27 opportunities observed. For Resident 4, a Licensed Vocational Nurse (LVN) crushed and prepared Metformin Extended Release (ER) and famotidine without verifying if they were crushable, which is against professional standards of practice. The nurse realized the error before administration, noting that crushing Metformin ER could cause a rapid drop in blood sugar and crushing famotidine could decrease its efficacy. The Director of Nursing (DON) confirmed that crushing these medications could result in less effective treatment for Resident 4's conditions, including diabetes and GERD. For Resident 10, another LVN failed to check the expiration date of diltiazem before administration. The medication, which was used to treat high blood pressure and chest pain, had expired. The LVN acknowledged that administering expired medication could cause nausea, vomiting, and reduced efficacy. The DON reiterated the importance of checking expiration dates to ensure resident safety and medication effectiveness. The facility's policy and procedure on medication administration emphasized the need to administer medications as ordered and in accordance with professional standards, including checking expiration dates and not crushing medications that should not be crushed. These failures had the potential to result in decreased medication efficacy for the residents involved. Resident 4 had severe cognitive impairment and was dependent on staff for self-care, while Resident 10 had fluctuating cognitive capacity and multiple heart-related diagnoses. The errors were identified during medication pass observations and interviews with the involved staff and the DON, highlighting lapses in following the facility's medication administration policies and procedures.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Medication Error Rate Exceeded Threshold During Eye, Ear, and Nebulizer Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

An LPN contributed to a medication error rate of 10.71% after 3 errors were found in 28 observed medication opportunities. The LPN administered eye drops and ear drops to one resident without preventing the resident from wiping the medication away, and left another resident unsupervised during a nebulizer treatment without monitoring the response or cleaning the equipment afterward. Record review showed the resident receiving the nebulizer had no documentation supporting self-administration, and the facility's procedures required assessment and direct administration for these treatments.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate, with surveyors identifying multiple dose discrepancies and an enteral medication error during observed med passes. An MA gave a resident the wrong ferrous sulfate dose, another MA gave a resident several medications at incorrect strengths, and an LVN used another resident’s MiraLAX and did not complete the ordered G-tube water flushes before administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication error rate exceeded the allowed threshold
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication error rate exceeded the allowed threshold. Surveyors calculated a 6.25% error rate based on 32 medication opportunities with 2 errors. In one case, an LPN gave a resident the wrong magnesium/calcium tablet strength compared with the active order for hypomagnesemia. In another, an LPN administered vitamin D3 400 units even though the resident’s order called for cholecalciferol 4000 units for vitamin D deficiency, and staff noted the pharmacy label still showed 400 units.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Threshold; Insulin Pen Not Primed and Inhaler Rinse Not Completed
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility’s medication error rate was 6.9%, with 2 errors found in 4 observed med passes. One nurse gave an insulin dose without priming the pen first, and another did not ensure a resident rinsed and spit after using a steroid-containing inhaler. The residents involved had DM and COPD, respectively, and both were moderately cognitively impaired.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Standard During G-Tube Medication Administration
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication Error Rate Exceeded Standard During G-Tube Medication Administration. Surveyors found a 27.59% medication error rate during observation of medication administration. An LPN crushed multiple meds together, mixed them with water, and administered them through a resident’s g-tube without giving each medication separately. The resident had encephalopathy, dysphagia, malnutrition, severe cognitive impairment, and required tube feeding for nutrition. The resident’s orders did not include permission to combine the tablets, and the DON and ADON stated meds for tube administration should not be cocktailed.

Inspection fine: $19,635
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeded Allowed Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Medication administration errors exceeded the allowed rate when seven errors were found in 31 opportunities. A nurse gave several scheduled meds to one resident more than 2 hours late, and another nurse crushed and gave three meds together through a G-tube to another resident instead of administering each med separately with flushes between doses, contrary to the DON’s expectations, the consultant pharmacist’s guidance, and facility policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.