F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
E

Inadequate Incontinence and Catheter Care

Broadview Multi Care CenterParma, Ohio Survey Completed on 04-01-2024

Summary

The facility failed to provide timely incontinence care for Resident #142, who had an indwelling catheter and was always incontinent of bowel. Observations revealed that the resident's incontinence brief was saturated with urine, and the reusable pad underneath was very wet. The resident reported discomfort due to the leaking catheter, which had been leaking for three days without being changed. The STNA confirmed the leakage and admitted to not checking the resident's incontinence brief during the night. The LPN acknowledged the catheter leakage but failed to document it or the new medication orders for bladder spasms in the resident's medical record. Resident #9, who had a suprapubic catheter, did not receive appropriate catheter care. Observations showed that the catheter bag was lying on the floor without a dignity cover, and the insertion site had bloody and mucous-like drainage with irritated and reddish skin. The STNA did not apply barrier cream after changing the resident's incontinence brief. The Unit Manager confirmed the lack of physician orders for cleansing the suprapubic catheter insertion site or for a dressing. Resident #76 was found wearing two incontinence briefs, with a large bowel movement noted in one of them. The STNA did not apply protective barrier cream after providing incontinence care. Resident #93, who passed away at the hospital, was admitted with massive amounts of powder and creams mixed with dried feces, leading to excoriation and pus in the groin area. The DON and Administrator acknowledged the condition but did not provide a satisfactory explanation for the lack of proper care. The facility's policy on incontinence care aimed to keep the skin clean, dry, and free of irritation and infection, but these standards were not met for the residents involved.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Catheter Bag Left on Floor Beside Bed
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with an indwelling urinary catheter, ordered for urinary retention related to hydronephrosis, was observed in bed with the catheter collection bag lying flat on the floor beside the bed and containing urine. The resident said an aide had helped her back to bed after breakfast, and one aide confirmed she assisted the resident but forgot to hang the bag from the bed frame as she normally would. The DON and Administrator stated catheter bags were expected to be kept off the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Care and Securement Not Maintained
E
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Catheter care and securement were not maintained for three residents with indwelling catheters. One resident's drainage bag was found lying in bed with tubing under the leg and no strap in place, another resident's tubing was under the leg with no strap present, and a third resident received catheter care from a CNA who cleansed the catheter using a back-and-forth motion and reused the same wipe instead of cleaning away from the penis in one direction. The DON and other staff stated the bag should be below the bladder, the strap should secure the tubing, and catheter care should be performed using proper technique.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Drainage Bag Positioned Above Bladder Level
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a catheter for neurogenic bladder, impaired cognition, and total bowel/bladder incontinence had a catheter drainage bag repeatedly observed hooked on a wheelchair arm rest above bladder level. The tubing contained urine that had not drained down, the resident tried to move the tubing to drain it, and staff interviews confirmed the bag should have been positioned below the bladder; one RN also stated the resident was on antibiotics for a bladder infection.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Foley Bag Placed at Bladder Level During Incontinent Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Foley Bag Placed at Bladder Level During Care: A resident with an indwelling Foley catheter, severe cognitive impairment, and obstructive uropathy had his drainage bag emptied and then placed on the bed at bladder level during perineal care. Observation showed urine moving back toward the catheter insertion site while the resident was repositioned. Staff interviews confirmed the bag should remain below the bladder at all times, and the facility policy required the drainage bag to be positioned lower than the bladder to prevent backflow.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Unsecured Foley Catheter and Incomplete Incontinent Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a Foley catheter was observed with the tubing not secured to the leg during care, and staff acknowledged it should have been secured to prevent pulling and injury. In a separate observation, two CNAs provided incontinent care to another resident with bowel incontinence and an indwelling catheter but did not clean the inner thighs or right buttock area before applying a clean brief, despite the care plan and facility policy requiring thorough perineal cleansing.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Bag and Tubing Left in Contact With Floor
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a catheter was observed with the catheter bag and tubing exposed outside the privacy bag and resting directly on the floor, and the resident moved the wheelchair over the bag. An RN later confirmed that catheter bag and tubing should not be in direct contact with the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Ohio

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Ohio — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙