F0759 F759: Ensure medication error rates are not 5 percent or greater.
D

Medication Administration Errors

Letcher ManorWhitesburg, Kentucky Survey Completed on 04-05-2024

Summary

The facility failed to ensure it was free of a medication error rate of five percent or greater. During a medication pass observation, there were nine instances out of 69 opportunities where medications were not administered according to manufacturer recommendations and/or the facility's medication policy, resulting in an error rate of 13.04%. This affected two residents, one of whom had their insulin injection prepared incorrectly, and another who did not receive the full dose of eight crushed medications. One resident, diagnosed with diabetes and chronic kidney disease, had an order for Tresiba insulin to be administered twice daily. However, during an observation, an LPN used a regular insulin syringe to draw up the insulin from a prefilled Tresiba flex pen, contrary to the manufacturer's recommendations. The LPN was unaware of the proper technique and the potential adverse reactions. The Director of Nursing and the Pharmacist confirmed that the correct method was to use needle adapters designed for the flex pen. Another resident had orders for eight different medications to be crushed and administered with food. During an observation, an LPN mixed the crushed medications with applesauce, but the resident did not consume the entire mixture, leaving approximately 25% of the medications in the cup. The LPN did not ensure that the resident received the full dose, which was against the facility's policy. The Director of Nursing stated that staff were educated on the proper administration of crushed medications and expected them to follow the facility's policies.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Omitted and Improperly Administered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed that an LPN committed three medication errors during 36 administration opportunities, resulting in a medication error rate above 5%. A resident with an order for crushed medications received Ingreeza prepared by softening the capsule in pudding instead of sprinkling the capsule contents as ordered. The same resident did not receive ordered Flonase nasal spray and olopatadine eye drops because the medications were not available. The ADON confirmed the improper Ingreeza administration as a significant medication error, and the NHA acknowledged that the facility exceeded the allowable medication error rate.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Exceeding Acceptable Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility failed to keep its medication error rate below 5%, finding three errors among 26 opportunities (11.45%). One resident with constipation did not receive a prescribed daily dose of polyethylene glycol when an RN mixed the laxative, placed it on the over-bed table, administered other meds, and left the room without giving it. Another resident with constipation received only part of a polyethylene glycol dose when an RN gave a single drink of the dissolved laxative, then left the remaining medicated solution at the bedside and exited the room. A third resident with GERD, ordered calcium carbonate 600 mg each morning, was administered 1000 mg when an RN used tablets labeled 1000 mg and later acknowledged not realizing a 600 mg strength existed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Result in Exceeding 5% Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed two medication administration errors that caused the facility’s medication error rate to exceed 5%. In one case, an LPN administered insulin using a pen device to a resident with diabetes without priming the pen as required by the manufacturer’s instructions. In another case, an LPN measured a resident’s ordered 17 g dose of MiraLAX by filling the product cap only partway instead of to the top rim as specified on the container, then administered the inaccurately measured dose. These actions resulted in a calculated medication error rate of 7.14% during the survey.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors Resulting in 14% Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors observed multiple medication administration errors resulting in a 14% error rate. One resident’s RN mishandled oral medications by touching pills with bare hands while searching for a diuretic, administered the diuretic after the resident had requested it be held, documented it as held on the MAR, and omitted an ordered nasal spray that was not available on the cart. The same RN failed to follow insulin lispro pen instructions, including not cleaning the rubber seal, priming the pen incorrectly, and not holding the injection site for the recommended time. For another resident, an RN initially prepared the wrong aspirin formulation (enteric-coated instead of chewable) before recognizing the discrepancy. These events occurred despite a policy requiring adherence to professional standards and accurate MAR documentation.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration and Documentation Errors Result in Elevated Medication Error Rate
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility’s medication error rate exceeded 5% after observing an RN administer a morning medication pass in which Duloxetine 60 mg, ordered to be given at bedtime for depression, was instead given in the morning, and Famotidine 20 mg, ordered once daily in the morning for GERD, was not observed being administered but was signed out as given on the MAR. These administration and documentation errors contributed to a calculated medication error rate of 6.45%.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙