Failure to Maintain Respiratory Equipment
Summary
The facility failed to ensure respiratory equipment was cleaned, changed, and stored per policy and manufacturer's recommendations for two residents. Resident #5, who was admitted with COPD, centrilobular emphysema, and diabetes type 2, had oxygen therapy equipment that was not dated or properly stored. Observations revealed that the oxygen nasal cannula tubing was on the floor, and the nebulizer mask was on the bedside table without proper dating. LPN #1 confirmed that the dating of the tubing was supposed to be done on the Sunday 11-7 shift but could not explain why it was not completed. The Director of Nursing Services (DNS) confirmed that the oxygen tubing should be changed and dated on the 11 PM-7 AM shift on Sunday night but was not aware of the specific reasons for the lapse in procedure. Resident #75, admitted with chronic obstructive pulmonary edema, dementia, and obstructive sleep apnea, had a CPAP machine that was not properly maintained. The CPAP mask and tubing were not labeled or dated, and the mask was not stored in a bag when not in use. LPN #2 indicated that the CPAP tubing and mask should be labeled and dated each week after cleaning and that the mask should be bagged when not in use. The DNS was unsure of the specific cleaning and changing schedule for the CPAP equipment and had to refer to the facility policy and manufacturer's recommendations. It was found that the CPAP equipment had not been cleaned or changed since admission, and the necessary physician orders for cleaning and maintenance were missing. The facility's policy and the manufacturer's recommendations for CPAP equipment maintenance were not followed, leading to the failure to clean and change the equipment as required. The DNS confirmed that the CPAP mask and tubing were not dated when last changed and that the filter had a layer of dust on it. The facility's policy required daily cleaning of the CPAP mask and tubing, weekly disinfection, and monthly changes of the white disposable filter. The DNS acknowledged the oversight and indicated that the necessary physician orders for the care and cleaning of the CPAP equipment would be added.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.