Frayed Bed Remote Wires Left in Residents’ Rooms
Summary
The facility failed to maintain electrical and patient care equipment in safe operating condition for five sampled residents by allowing bed remote controls to remain in disrepair with frayed or exposed wires. During observations, Resident 76, Resident 31, Resident 2, Resident 15, and Resident 49 each had a bed remote control that showed frayed wiring near the control pad or exposed inner wires. For Resident 49, the LVN immediately removed the remote from the resident’s reach and notified maintenance after observing the exposed wires. The affected residents had diagnoses and assessments showing varying levels of cognitive impairment and need for assistance. Resident 76 had diagnoses including dementia, disorientation, and adult failure to thrive, and the H&P stated the resident did not have capacity to make decisions. Resident 31 had diagnoses including atrial fibrillation, dementia, and major depressive disorder, and the H&P stated the resident did not have capacity to understand and make decisions. Resident 2 had diagnoses including cognitive communication deficit, dementia, and aphasia, with the H&P stating the resident was awake, alert, oriented, and had capacity. Resident 15 had diagnoses including dementia, major depressive disorder, and psychosis, and the H&P stated the resident did not have capacity to understand and make decisions. Resident 49 had diagnoses including hemiplegia, type 2 diabetes mellitus, and hypertension, and the MDS showed dependence for several activities of daily living and moderate cognitive impairment. Each resident’s care plan or related documentation included expectations for a safe environment or functional adaptive equipment. The facility’s staff and leadership acknowledged during interviews that frayed or exposed wires on bed remote controls should not be present because they can cause electrical shock or electrocution. The ADON stated the facility did not follow the care plans related to providing a safe environment, and the DON stated maintenance was responsible for the equipment, while staff should also report hazards. The facility policy stated maintenance was responsible for keeping buildings and equipment safe and operable, and the bed manufacturer’s manual instructed inspection of bed components and electrical cords for damage, chafing, cuts, or excessive wear.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.