Infection control failures during PPE handling and glucometer use
Summary
The facility failed to follow infection control guidelines during care of residents on droplet or contact/droplet precautions. R34 was admitted with Parkinson's disease and severe protein calorie malnutrition and later tested positive for COVID-19. During observation, a CNA and a housekeeper exited R34's room after providing care and removed the goggles they had worn inside the room, then wiped the goggles with a Sani-Cloth wipe from the orange-top container for 90 seconds before placing them directly into the isolation cart with clean, unused PPE. During the same resident's care, an OT was observed in the room assisting the resident while wearing a surgical mask. The Infection Preventionist later confirmed that the goggles should have been cleaned with a wet Sani-Cloth from the orange-top container for four minutes and that the OT should have worn an N95 mask instead of a surgical mask. R51 was admitted with unspecified sequelae of other nontraumatic intracranial hemorrhage and atrial fibrillation and later tested positive for COVID-19. The physician ordered contact/droplet isolation with 10-day monitoring. During observation, the CNA exited R51's room after care, removed the goggles worn in the room, wiped them with a Sani-Cloth wipe from the orange-top container for 90 seconds, and placed them directly into the isolation cart with clean PPE. R77 was admitted with COPD and later tested positive for COVID-19, with a physician order for contact/droplet isolation and 10-day monitoring. During observation, the same CNA exited R77's room, removed the goggles worn in the room, wiped them with a Sani-Cloth wipe from the orange-top container for 90 seconds, and placed them directly into the isolation cart with clean PPE. The facility also failed to ensure glucometer checks were performed in a manner to prevent infection for R60, who was admitted with diabetes. An LPN removed the glucometer from the medication cart drawer and placed it on top of the cart without a barrier, then placed it into her pocket and applied gloves without using hand sanitizer before entering the resident's room. In the room, the glucometer was placed on the resident's overbed table. After obtaining the blood sugar result, the LPN returned the glucometer to the medication cart drawer without cleaning it. The LPN later confirmed she should have cleaned the glucometer with the specialized wipes on the cart, and the unit manager confirmed the infection control practices were not maintained during the glucometer check.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.