Resident Fall From Mechanical Lift Due to Inadequate Sling Security and Supervision
Summary
The deficiency involves the facility’s failure to ensure a resident remained free from accident hazards and received adequate supervision during a mechanical lift transfer, resulting in a fall and head injury. The resident had significant medical conditions including DM2, prior stroke with hemiparesis and hemiplegia affecting the right dominant side, and a malignant brain neoplasm. The resident’s MDS documented moderately impaired cognition, dependence on staff for all care and transfers, and use of a wheelchair for locomotion. The care plan identified the resident as at risk for falls due to stroke-related deficits and required staff assistance with all transfers, specifying use of a total mechanical lift with two staff and a large sling, with staff ensuring proper positioning in the sling before bearing weight. On the morning of the incident, two staff (a CNA and a CMA) were transferring the resident from bed to wheelchair using a full-body mechanical lift. The CNA reported standing close to the resident while the CMA operated the lift controls. After the resident was lifted off the bed, the lift was pulled away from the bed to make room for the wheelchair. The CNA turned away to get the wheelchair and then heard the CMA scream; when she turned back, the resident was partially hanging from the lift with feet in the air and head on the ground, with only two sling loops still attached. The CMA reported that when the CNA let go of the resident and turned to get the wheelchair, the resident rolled to the side in the sling, the sling became partially undone, and the resident fell, striking the back of the head on a leg of the lift. The CMA recalled that three of the four sling loops remained connected after the fall. The nurse who responded found the resident on the floor between the legs of the lift and documented two hematomas on the back of the resident’s head. The facility’s equipment and documentation further contributed to the deficiency. Observation of the full-body lifts in service showed that the hook assemblies used to attach sling loops lacked any mechanism to prevent sling loops from unintentionally coming loose during transfers. The facility’s Safe Resident Handling Program policy required caregivers to perform a “TIME OUT” safety stop while the resident was still over the bed or chair surface, with straps taut, to ensure the straps were secure before moving away from the surface. Administrative staff stated that staff were expected to pause for approximately 30 seconds after lifting the resident free of the surface to double-check that sling loops had not come undone before proceeding with the transfer. The fall report and Fall Scene Huddle Worksheet for this incident did not contain evidence that an investigation was performed or that a root cause of the fall was identified, and there was no documented determination of why the sling loops became detached during the transfer.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.