F0908 F908: Keep all essential equipment working safely.
F

Kitchen Equipment Not Maintained in Safe Operating Condition

Sequoias San Francisco Convalescent HospitalSan Francisco, California Survey Completed on 02-17-2026

Summary

The facility failed to maintain kitchen electrical and mechanical equipment in safe operating condition when the dishmachine had leaking parts and a light cover under a vent hood was missing. Review of facility policies showed that essential equipment repairs were to be initiated by Maintenance within 24 hours and that proper maintenance of the physical plant and all equipment in the department was the responsibility of the Director in cooperation with Maintenance. The 2022 Federal Food Code was also cited as requiring equipment to be maintained in a state of repair. During observation in the kitchen, the dishmachine was in use and the dish room floor was very wet. A later observation showed a pipe under the dishmachine leaking, and water dripping from the counter on the clean side of the dishmachine. The Executive Chef confirmed the drainpipe was leaking and thought there was a crack in the counter where water was getting through. The Director of Dining Services stated the dishmachine had been leaking for a long time but had not been reported. In a separate observation, multiple lights under a vent hood were seen over cooking equipment, and one light cover was missing so the bulb was exposed. The Director of Dining Services stated maintenance had been informed of the missing hood light cover, and the Maintenance Manager stated he was aware of the missing cover and was looking for one.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0908 citations
Inoperable Commercial Washer in Laundry Department
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

In the laundry department, 1 of 2 commercial washers was out of service for more than 8 months, leaving only 1 washer available for resident laundry. Laundry Aides stated they used the working washer for all residents and that keeping up with timely laundry services was sometimes challenging with only 1 machine.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Hoyer Lift Batteries Not Maintained in Safe Operating Condition
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

A resident who required a mechanical lift for transfers experienced repeated Hoyer lift battery failures during transfers, including one observed transfer where the lift stopped working while he was being lowered. Staff reported that lift batteries were often not charged, that overnight staff were responsible for charging them, and that they sometimes used the emergency release to lower the resident when the battery died. The DON and other staff confirmed the batteries were not consistently checked or maintained, and the maintenance supervisor said batteries were only replaced occasionally.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Flooring Renovation Started Before Construction Review Approval
E
F0908 F908: Keep all essential equipment working safely.
Short Summary

Flooring Renovation Started Before Construction Review Approval: The facility removed carpet and installed laminate flooring in resident areas before receiving DOH Construction Review Services approval. The Administrator said the second-floor west unit remodeling had already been completed and residents were moved to another unit during the work. Notices to residents described planned flooring replacement, observation confirmed new wood flooring in the hallway and resident rooms, and a resident said they were relocated for at least two weeks. The Regional Plant Operations Director stated the approval was still pending and that they were unsure of the approval process.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Laundry Equipment Not Maintained in Safe Operating Condition
E
F0908 F908: Keep all essential equipment working safely.
Short Summary

Laundry equipment was not maintained in safe operating condition. A resident with ESRD on dialysis reported that clothes came back stinking, while the Laundry Supervisor said the industrial washer kept breaking down, hot water was not getting hot, the wrong soap was being used for resident clothing, and the department lacked a hopper for washing soiled linens. Observation showed a small washer overfilled with sheets, and staff gave mixed reports about washer breakdowns and linen shortages.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Mechanical Lift Found With Exposed Charging Cord
D
F0908 F908: Keep all essential equipment working safely.
Short Summary

Mechanical lift equipment on the 3rd floor was observed with exposed black and red inner cords from the grey charging cord hanging out. An RN said the lift should not be used if the cords are exposed, and the DON stated such equipment should be reported to maintenance and removed from the floor for safety precautions. The Maintenance Director confirmed the outer grey cord protects the inner cords, and the maintenance log showed no repair report for the lift.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Ambu Bags Found on Two Crash Carts
E
F0908 F908: Keep all essential equipment working safely.
Short Summary

Expired Ambu Bags Found on Two Crash Carts: The facility failed to ensure two crash carts were in safe operating condition when an Ambu bag on the First Floor Crash Cart and an Ambu bag on the Second Floor Crash Cart were both found expired. RN staff confirmed the expired equipment and acknowledged the carts were not maintained as required by the facility's crash cart management process.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙