F0759 F759: Ensure medication error rates are not 5 percent or greater.
E

Medication Error Rate Exceeded Limit Due to Expired Folic Acid and Incorrect Inhaler Dose

Foundation Skilled NursingFresno, California Survey Completed on 12-09-2025

Summary

The facility failed to keep the medication error rate below 5 percent; surveyors calculated an 8 percent medication error rate based on 25 opportunities for error and two medication errors involving one resident. During an observation and interview, an LVN prepared five tablets of Folic Acid 1 mg for a resident and did not check the expiration date before medication administration. The medication card was later found to have an expiration date of 11/5/25, and the LVN stated the medication had been expired and that she was not checking expiration dates during the medication pass. The same resident also received an incorrect dose of Tiotropium Bromide Monohydrate inhalation medication. During the medication pass, the LVN asked the DON how to prepare the inhaler medication and stated she had not received training on it. The LVN administered one inhalation to the resident and later signed the EMAR indicating all morning medications had been given. When questioned, she stated she had mistakenly administered only one inhalation instead of the ordered two inhalations and acknowledged that the resident did not receive the full dosage. The resident involved had diagnoses of anemia and COPD and a BIMS score of 4, indicating severe cognitive impairment. The DON stated it was her expectation that licensed nurses check expiration dates before administering medications and follow physician orders so residents receive the full effectiveness of prescribed medications. The facility policy required medications to be administered as prescribed, with the label checked three times and the expiration or beyond-use date checked prior to administration.

Penalty

Inspection fine: $51,88014 days payment denial
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Ensure Accurate Medication Dosage Identification During Medication Pass
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to maintain medication error rates below 5% when an LPN, during a medication pass for a resident receiving Metamucil for constipation and a cranberry supplement for UTI prevention, was unable to identify the correct dosages for these ordered medications. Despite a policy requiring adherence to the rights of medication administration, including the right dose, the LPN reported that the orders should have been clarified to specify the exact dose, indicating medications were being prepared and administered without clear dosage understanding and contributing to an overall medication error rate above the acceptable threshold.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Acceptable Medication Error Rate and Proper Medication Timing
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility did not maintain a medication error rate below 5%, identifying multiple late and improperly timed medication administrations and a missing medication. A medication aide gave a cholesterol medication and wound-healing supplements significantly later than their scheduled times, and another aide administered acetaminophen well outside the ordered time window and could not obtain a prescribed dose of Ingrezza because it had not arrived from the pharmacy. An LPN administered fast-acting Humalog insulin before a meal when no food was available and was unaware of the required timing of insulin in relation to meals, while the facility’s insulin policy lacked guidance on meal-related timing despite manufacturer instructions specifying administration within 15 minutes before or immediately after eating.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Above 5% Due to Incorrect Dosing and Insulin Pen Technique
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified a medication error rate of 7.41%, exceeding the 5% threshold, involving two residents and two LPNs. In one case, a resident with dementia and hypertension received 5 mg of donepezil instead of the 10 mg dose ordered. In another case, a resident with DM2 received insulin lispro via a KwikPen that was not primed, and the LPN held the dose knob for only about 2 seconds instead of the manufacturer-recommended 5 seconds. The DON reported that staff had not been educated on proper insulin pen priming, and facility policy requires verification of the correct medication and dose before administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors and Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified an 11.1% medication error rate when an LPN did not administer a resident’s ordered nifedipine ER dose because it was not available in the cart or pyxis, and proceeded with the rest of the medications. In a separate instance, an RN administered furosemide despite the order having been discontinued and gave magnesium oxide instead of the ordered SlowMag, explaining that he relied on scanning multi-drug packets rather than individually verifying each medication against the MAR, and knowingly substituted magnesium oxide when SlowMag was unavailable.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to keep its medication error rate below 5% when a resident with dementia, COPD, diabetes, and depression did not receive ordered doses of Singulair and calcium/vitamin D3 because the medications were not available at the time of administration. An RN attempted to pass the morning medications but was unable to administer these two ordered drugs, and later confirmed their unavailability, resulting in two errors out of 33 medication opportunities and an overall error rate of 6.06%.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across California

Get a heads-up on the newest immediate-jeopardy (J–L) citations in California — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙