Infection Control Failures During Resident Care and Medication Administration
Summary
The facility failed to implement its infection prevention and control program for multiple residents during medication administration and resident care activities. Resident 103, who had been the roommate of Resident 132 after Resident 132 returned from the hospital with a positive Covid-19 result, was tested once for Covid-19 on 9/10/25 with negative results but was not tested again on 9/12/25 and 9/14/25 as identified by the Infection Preventionist Nurse and Infection Preventionist Consultant. The Director of Nursing stated the expected testing schedule for the exposed resident should have been day 1, day 3, and day 5. Resident 15 had an order for Enhanced Barrier Precautions during high-contact care activities. During medication administration through the G-tube, LN 35 entered the room wearing gloves but without a precaution gown, despite an EBP sign on the door stating staff must clean hands, wear a gown, and wear gloves for high-contact care. LN 35 later stated she should have worn a gown while providing care to the resident. Resident 113 and Resident 82 were both on EBP-related precautions, and LN 36 used a personal blood pressure device brought from home to obtain blood pressures for both residents. The device had a soft fabric cuff that could not be properly sanitized, and LN 36 did not clean it between use on the two residents. Resident 10’s medication administration also involved improper glove use and hand hygiene, as LN 37 removed gloves, retrieved an item from the medication cart, applied a new pair of gloves without performing hand hygiene, and continued care in the resident’s room. Resident 140 received oral medications and then erythromycin ophthalmic ointment while LN 39 wore the same pair of gloves and handled items on the bedside tray before applying the eye ointment. Resident 4, who had asthma, immunodeficiency, and an order for nebulized ipratropium-albuterol, was on EBP. During nebulizer treatment, LN 38 entered the room with a precaution gown that was not tied and was falling off her shoulders. LN 38 dropped a nebulizer piece on the floor, picked it up, rinsed it in the bathroom, and used the same piece for the resident’s treatment. The resident later placed a hand on LN 38’s exposed scrub top while the gown remained unsecured. LN 38 stated she should have discarded the dropped piece and used a new one, and the DON stated the gown should have been tied and secured.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release October 8, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.