Respiratory equipment not implemented as ordered and not maintained clean
Summary
Safe and appropriate respiratory care was not provided for two residents when respiratory equipment was not implemented as ordered and was not maintained in a clean and functional manner. The facility’s oxygen management policy required oxygen to be administered by physician order, oxygen tubing to be changed weekly or when soiled or damaged, and concentrator filters to be cleaned weekly or per manufacturer recommendations. No documentation was found describing how CPAP machines were to be maintained. Resident 27 had diagnoses including diabetes and obstructive sleep apnea and was fully dependent on staff for bathing, repositioning, and transfers. The medical record included an order for CPAP use every night shift, but the MAR showed the CPAP was used on some nights and not used on others. The resident stated multiple times that they did not wear the CPAP every night because they forgot to ask staff, needed staff help to put it on, and staff did not offer or remind them. Observations showed the CPAP lying in the resident’s nightstand drawer and later on the nightstand with no strap on the mask; the resident stated the strap was missing and that they had not used the CPAP because they still did not have a strap to hold the mask in place. Staff B later acknowledged that the CPAP could not have been used as documented because all parts were not available. Resident 43 had diagnoses including heart failure, diabetes, and stroke and was cognitively intact and dependent on supplemental oxygen. The provider ordered oxygen tubing to be changed weekly, and the care plan directed staff to monitor for signs and symptoms of infection. Observations showed the oxygen tubing was dated 17 days earlier than the observation date, and the oxygen concentrator was unclean with white splatter and thick dust debris in the filter area. Similar observations of the dated tubing and unclean concentrator were made repeatedly over multiple days. Staff D stated tubing was changed weekly and concentrators were wiped down nightly and when dirty, and Staff B stated oxygen tubing was changed weekly.
Penalty
Resources
Below are regulatory guidelines relevant to this citation:
Trusted data from CMS and state health departments
Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release July 29, 2026) and official state health department websites — never guesswork.
In your survey window? See what surveyors are citing.
The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.