Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
F0880
D

Failure to Follow Infection Control Practices During Blood Glucose Monitoring

Granite Falls, North Carolina Survey Completed on 05-21-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to properly clean and disinfect an individually assigned glucometer according to the manufacturer's recommendations and did not follow its own infection control policy regarding glove use during blood glucose monitoring. Specifically, a nurse used alcohol-based hand disinfectant wipes, which were not listed as an approved disinfectant by the glucometer manufacturer, instead of the required Super Sani-cloth Germicidal disposable wipes that were available on the medication cart. The nurse was unaware of the manufacturer's specific disinfection instructions and believed the hand disinfectant wipes were sufficient. Additionally, the nurse performed a blood glucose check on a resident while wearing a torn glove, contrary to the facility's policy that requires gloves to be changed if torn or damaged. The torn glove was used throughout the procedure, including when obtaining a new test strip and performing a second blood glucose check after an initial error. The nurse was not aware that her glove was torn during the procedure. The Director of Nursing confirmed that the expectation was for intact gloves to be used and for the manufacturer's disinfection instructions to be followed.