Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0345

Failure to Maintain Fire Alarm System Documentation

West Chester, Pennsylvania Survey Completed on 08-05-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain the fire alarm system in accordance with NFPA 70 and NFPA 72 requirements, as evidenced by the absence of documentation for a semi-annual visual inspection of the fire alarm system. During a document review and interviews, it was determined that the facility could not provide records of the required inspection for all seven smoke compartments. This lack of documentation was confirmed during interviews with the Administrator, Regional Director, Regional Maintenance Director, and Environmental Services Director at the time of the survey exit conference. No information regarding specific residents, their medical history, or their condition at the time of the deficiency was provided in the report.

Plan Of Correction

The facility failed to maintain the fire alarm system, for seven of seven smoke compartments. No residents were affected by this deficient practice. All residents have the potential to be affected. On 8/12/2025, the Maintenance Director was educated by the Administrator on the requirement that a semi-annual visual inspection of the fire alarm system is required. A semi-annual visual inspection of the fire alarm system was completed. Fire alarm system was audited to ensure compliance with the requirement. The Maintenance Director/Designee will conduct compliance audits semi-annually on an ongoing basis to ensure that a semi-annual visual inspection of the fire alarm system is completed. Results of audits will be reviewed at Quarterly Quality Assurance and Performance Improvement Committee Meeting over the duration of the audit process. Based on the results of these audits, a decision will be made regarding the need for continued submission and reporting.