F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
D

Failure to Provide Appropriate Catheter Care and Privacy for Residents

Asbury Health CenterPittsburgh, Pennsylvania Survey Completed on 06-26-2025

Summary

The facility failed to provide appropriate treatments and services for residents with indwelling urinary catheters, as required by both federal and state regulations. Specifically, two residents with complex medical histories, including chronic kidney disease, urinary tract infections, and obstructive and reflux uropathy, did not receive care in accordance with facility policies. Documentation was lacking regarding catheter removal procedures, including assessment data, resident tolerance, and post-removal monitoring. For one resident, after a foley catheter was discontinued, there was no evidence that staff offered frequent toileting attempts or documented assistance with continence or incontinence, despite orders for bladder scans and fluid intake. This resident ultimately required re-insertion of the catheter due to incomplete bladder emptying. Observations revealed that both residents with indwelling catheters did not have their catheter drainage bags covered with dignity bags for privacy, as required by facility policy. On multiple occasions, the catheter bags were visible and not shielded from view, either hanging on a wheelchair, walker, or bed frame. Staff interviews confirmed that the required privacy measures were not consistently implemented. The Director of Nursing acknowledged that the facility did not ensure appropriate treatment and services for the two residents with indwelling urinary catheters. The deficiencies were also found to be in violation of several Pennsylvania state codes related to management, resident care policies, and nursing services.

Plan Of Correction

R331's MD was notified of concern having orders for output, measuring and recording of urinary output for resident's catheter management. R51 was provided with a Foley privacy bag. All residents with Foley catheters were audited for privacy bags and Foley management orders reviewed to ensure output documentation within a 24-hour period is inclusive. DON or designee will educate nurses on proper Foley catheter management including documentation of output for all residents with a Foley catheter and proper placement of catheters in a dignity bag. Facility IP or designee will audit all Foley catheter residents for appropriate chart documentation and privacy bags 1 time a week for 4 weeks, then monthly for 2 months. Results will be reviewed at QAPI and revised as needed.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0690 citations
Improper catheter drainage bag handling and emptying
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with an indwelling catheter and severe cognitive impairment had catheter drainage care observed to be inconsistent with the care plan and facility policy. An RN placed the urine graduate on the floor while emptying the leg bag and did not cleanse the drainage outlet with an alcohol swab, and the resident’s drainage bag was later observed lying directly on the floor instead of being kept in a privacy bag or hung on the bed frame.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Monitor Catheter-Associated UTI Signs
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Failure to Monitor Catheter-Associated UTI Signs: A resident with dementia, muscle weakness, and protein-calorie malnutrition had a physician order to monitor and report signs of catheter-associated UTI, but staff did not complete the ordered monitoring. The resident was observed with white, milky urine in the catheter tubing and bag on multiple days, the MAR showed the monitoring order was not completed, and the CNO stated the cloudy urine was the resident’s baseline and that no physician notification was documented.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide and Document Condom Catheter Care
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Failure to provide and document condom catheter care for a resident with stroke, contractures, cognitive communication deficit, kidney disease, and chronic sacral ulcers. The resident had a condom catheter placed to help with bladder incontinence and sacral ulcer healing, but the physician orders did not identify the catheter or required care, the care plan only addressed patency, urine output, and skin checks, and the chart lacked catheter care, catheter changes, and skin assessments for an extended period. An incident report showed the catheter became dislodged and caused a 7 cm penile laceration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Inadequate catheter and perineal care
E
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Inadequate catheter and perineal care was observed for multiple residents with urinary devices and incontinence needs. A resident with an indwelling catheter had cloudy urine, sediment, bleeding, pain, and an unsecured catheter after staff reportedly pulled on it during care. Other residents were found with urine- and stool-soiled clothing, bedding, and catheter dressings, leaking or dangling urinary tubes, delayed brief changes, and incomplete peri-care that did not include the full frontal perineum, labial folds, urethra, or catheter area.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Catheter Bag Resting on Floor
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

A resident with a suprapubic indwelling catheter, bladder dysfunction, and a recent UTI was observed in the dining room with the catheter drainage bag hooked to the wheelchair and resting in direct contact with the floor on more than one occasion. Staff, including a CNA, an LPN, and the DON, acknowledged the bag should not have been on the floor, and the facility policy and CDC guidance cited in the report state the drainage bag should be kept below the bladder and not rested on the floor.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Nephrostomy Drainage Positioning
D
F0690 F690: Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
Short Summary

Improper Nephrostomy Drainage Positioning: A resident with MS, neurogenic bladder, and a left nephrostomy tube had the drainage bag hung from a wheelchair armrest with tubing positioned above the insertion site, preventing dependent urine drainage. A TMA said this was the usual setup, and the RNCM and DON confirmed the bag and tubing were incorrectly positioned and not allowing urine to drain appropriately.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Citation search

Search every citation & Plan of Correction

Go to search
Citation watch

Track new serious citations across Pennsylvania

Get a heads-up on the newest immediate-jeopardy (J–L) citations in Pennsylvania — where surveyors are focused right now.

Free · about one email a month

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release August 26, 2026) and official state health department websites — never guesswork.

In your survey window? See what surveyors are citing.

The Survey-Prep Report maps your facility's risk from 12 months of CMS and state citation data — what's being cited around you and what to check first. $129 one-time.

Get the Survey-Prep Report
An unhandled error has occurred. Reload 🗙

Connection lost — reconnecting… We couldn't reconnect automatically. Please reload the page to continue.