Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0353
E

Failure to Maintain and Test Sprinkler System Gauges

Lehigh Acres, Florida Survey Completed on 06-16-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

During an unannounced Fire & Life Safety relicensure survey, surveyors identified that the facility failed to maintain its automatic fire sprinkler system in accordance with National Fire Protection Association (NFPA) 101 standards. Specifically, the sprinkler gauge on the backflow and the gauges on the riser were observed to be dated from 2019, indicating that they had not been replaced or tested within the required five-year interval. Documentation provided by the facility did not include evidence of the mandatory five-year gauge testing. The deficiency was confirmed through record review, direct observation, and staff interviews. The Maintenance Director, who accompanied the surveyors during the facility tour, acknowledged the findings and stated that he was unaware if the gauges had been tested as required. Photographic evidence was obtained to support the observations made during the survey. The report references multiple applicable codes and standards, including NFPA 101 (2021 Edition), NFPA 13 (2019 Edition), and NFPA 25 (2020 Edition), all of which require regular inspection, testing, and maintenance of water-based fire protection systems. The lack of current testing records and outdated gauges constituted a failure to meet these licensure requirements. No information regarding specific residents or their conditions was included in the report.

Plan Of Correction

No individual residents appear to be affected as no residents were noted. All residents have the potential to be affected. The maintenance director contacted a third-party vendor, and all three identified gauges were replaced on 07/10/2025. Re-education will be completed by the administrator with the maintenance staff regarding maintaining the automatic fire sprinkler system in accordance with NFPA 101 standards by 07/25/2025. The Maintenance Director will audit the sprinkler system to ensure it is maintained in accordance with NFPA 101 standards monthly for three months. Results of the audits will be reviewed by the QAPI committee monthly for three months and randomly thereafter. Date of completion 07/25/2025.