Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0374
E

Smoke Barrier Door Deficiencies

Bryn Mawr, Pennsylvania Survey Completed on 04-15-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain smoke barrier doors to resist the passage of smoke, affecting one of three levels. During an observation on April 15, 2025, it was noted that a smoke barrier door on the first floor next to room 112 was blocked by a wheelchair, preventing it from closing smoke tight. Additionally, the smoke barrier door in the Chateau Dining area was dragging on the floor, which also prevented it from closing smoke tight. These deficiencies were confirmed during an exit interview with the Administrator, Maintenance Director, and Regional VP of Operations.

Plan Of Correction

1) A. Immediately upon observation on April 15, 2025, the wheelchair next to room 112 was removed so as not to prevent the door from closing smoke tight. B. Chateau Dining the smoke barrier door was repaired so that it does not drag the floor, preventing the door from closing smoke tight. 2) The Maintenance Director and/or designee audited all smoke doors for obstructions and door dragging the floor preventing the door from closing smoke tight. 3) To prevent the potential for reoccurrence, the Administrator and/or designee educated the Maintenance Director and/or designee and staff on the importance of all smoke doors closing smoke tight without obstructions. 4) To monitor and maintain ongoing compliance, the Maintenance Director and/or designee will audit 3 smoke doors for closing smoke tight without obstruction for the next 3 months. If an issue is identified, the Maintenance Director or designee will immediately notify the administrator and correct the problem. Findings will be reported to facility QAPI for continued review and recommendations.