Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0363
E

Deficiencies in Corridor Door Maintenance

Stevens, Pennsylvania Survey Completed on 03-31-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility was found to have deficiencies related to the maintenance of corridor doors, which are crucial for fire safety and smoke containment. On March 31, 2025, an observation revealed that the stairtower doors on the 1st floor, near Resident Room 215, had gaps greater than the allowed 3/16 inch. This was confirmed by an interview with the Director of Maintenance, indicating that the doors exceeded the permissible gap margins, thus failing to meet the National Fire Protection Association (NFPA) 101 standards for corridor doors. Additionally, further observations on the same day revealed that the corridor doors to Resident Rooms 215 and 205 failed to close and latch properly. These findings were also confirmed through interviews with the Director of Maintenance. The inability of these doors to close and latch compromises their effectiveness in resisting the passage of smoke, which is a critical safety requirement, especially in fully sprinklered smoke compartments. These deficiencies highlight a failure in maintaining the required safety standards for corridor doors within the facility.

Plan Of Correction

1. The corridor doors to Resident Rooms 205 and 215 have been adjusted to close and latch. 2. The corrective action was completed on 4/1/2025. 3. The Maintenance Director or Designee will conduct a facility wide audit of all facility corridor doors for closure and latch then random door checks monthly. 4. Findings of Audits will be submitted to QAPI for review.