K0918 K918: Have generator or other power source capable of supplying service within 10 seconds.
F

Failure to Maintain Emergency Power System

Osprey Point Nursing CenterBushnell, Florida Survey Completed on 03-11-2025

Summary

The facility failed to maintain the emergency and standby power system as required by NFPA 110. During a record review with the Maintenance Director, it was found that the facility could not provide documentation for the weekly emergency backup generator testing. This lack of documentation indicates that the required testing was not being conducted as per the standards set by NFPA 110. In an interview, the Maintenance Director admitted that the facility had not been performing the weekly tests or voltage checks on the emergency backup generator. This deficiency was discussed with both the Administrator and the Maintenance Director during the exit conference, highlighting a significant lapse in the facility's adherence to essential electrical system maintenance protocols.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
See other K0918 citations in Ohio
Failure to Maintain and Document Required Generator Testing and Safety Features
F
K0918 K918: Have generator or other power source capable of supplying service within 10 seconds.
Short Summary

Surveyors found that the facility failed to maintain required documentation showing that its three generators were tested monthly and inspected and tested annually in accordance with NFPA 99 and NFPA 110. Despite multiple requests, no records of these tests or inspections were provided. During the facility tour, surveyors also observed that none of the three generators were equipped with remote manual stop buttons, and this was confirmed by the Maintenance Director. This deficient practice had the potential to affect all residents in the facility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Required Generator Load Bank Testing and Documentation
F
K0918 K918: Have generator or other power source capable of supplying service within 10 seconds.
Short Summary

The facility did not complete the required four-hour load bank test of its diesel generator within the mandated 36-month period and failed to properly document engine hours during monthly tests, as confirmed by the Maintenance Director. This lapse affected the reliability of the essential electrical system for all residents.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

65.1% of Ohio facilities received at least one citation during their inspection in the last 12 months.Will yours be survey-ready?

Surveyors issued 55 serious citations across Ohio in the last 12 months. See exactly what they're citing.

Get ready for your next survey

See what surveyors are citing in Ohio and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release May 27, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙