Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0100
E

Failure to Obtain Approval for Room Use Changes

Kittanning, Pennsylvania Survey Completed on 12-18-2024

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain general requirements of the life safety code on two of six building levels. On December 18, 2024, it was observed that the basement floor seamstress room and mechanical equipment room were converted to storage locations containing combustible materials, which do not meet hazardous area requirements. The facility changed the use of these rooms without obtaining the necessary approval from the State Plan Review and a granted occupancy from the Division of Life Safety. Additionally, the facility did not obtain the required approval for changing the use of resident rooms to storage rooms on the fifth floor. Interviews with the administrator and maintenance director confirmed that the facility did not submit the required paperwork for these room changes.

Plan Of Correction

1. Maintenance Director immediately removed combustible materials from the basement area. 2. The approval of the state plan review with granted occupancy that was granted on 8/13/24 from the Life Safety Division will be placed in the Emergency Preparedness Binder. An additional request for approval for the change of use of the 5th floor will be submitted to plan review requesting the occupancy change. 3. Maintenance Director or designee will audit for appropriate storage in the basement area weekly x 4 weeks and monthly x 1 month. 4. Results will be discussed with QA committee with monitoring if applicable.