Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0911
E

Electrical System Deficiencies in Facility

Wyndmoor, Pennsylvania Survey Completed on 01-27-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain electrical equipment, as observed during a survey on January 27, 2025. The deficiencies were noted on two of the four levels of the facility. In the basement boiler room, an unsecured junction box was found resting on top of the middle boiler. On the second floor, above the smoke doors near the nurses' station, electrical tape was improperly used to secure a junction box cover instead of using appropriate screws. Additionally, in the Activities Department, an electric baseboard heater was improperly placed on top of an abandoned heating register, with exposed Romex wiring, and surrounded by combustible materials, including cardboard. These observations were confirmed during an exit interview with the Administrator and Maintenance Director on the same day.

Plan Of Correction

1. The open junction box in the basement boiler room was immediately secured. Appropriate screws were installed on the second floor, above the smoke doors to the left of the nurses' station, to secure a junction box. The heater inside the Activities Department was repaired to ensure compliance. 2. Electrical equipment throughout the facility audited to ensure compliance. 3. Education will be provided to ensure proper compliance with this regulation. 4. An audit of the junction box in the boiler room and the heater in the Activities Department will be conducted to ensure compliance. Audit will be done 2x a month for 2 months and 1x a month for 1 month. 5. The findings of these quality monitoring's to be reported to the Quality Assurance/Performance Improvement Committee monthly x6 months.