Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0353
E

Sprinkler System Maintenance Deficiencies

Scranton, Pennsylvania Survey Completed on 01-07-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain the automatic sprinkler system in three specific locations, affecting three out of six floors. During an observation on January 7, 2025, several deficiencies were noted: the make-up air room in the basement lacked a suspended ceiling assembly with surface-mounted sprinkler heads; a plastic bag material was found affixed to an automatic sprinkler head in the fifth-floor Personal Laundry; and a sprinkler head assembly in the first-floor Dietary Office was missing an escutcheon plate. These deficiencies were confirmed during an exit interview with the Facility Administrator and the Facilities Manager.

Plan Of Correction

Observation 1: The make-up air room, located at the basement level, lacked a suspended ceiling assembly (surface-mounted sprinkler heads). 1) What systematic changes will be put into place to ensure that the deficiency does not recur, and how the corrective action(s) will be monitored? The current 2 sprinkler heads in the air make-up room are scheduled to be inverted to upright heads. The remainder of the drop ceiling will be removed. Sprinkler head and in-house fire inspections will be completed quarterly. The Director of Facilities Management will report the inspection findings to the QAPI committee. Observation 2: Plastic bag material was affixed to an automatic sprinkler head, located within the fifth floor Personal Laundry. 1) What systematic changes will be put into place to ensure that the deficiency does not recur, and how the corrective action(s) will be monitored? Plastic bag material was removed from the automatic sprinkler head in the fifth floor personal laundry area. Sprinkler head and in-house fire inspections will be completed quarterly. The Director of Facilities Management will report the findings to the QAPI committee. Observation 3: A sprinkler head assembly, located within the first floor Dietary Office, lacked an escutcheon plate. 1) What systematic changes will be put into place to ensure that the deficiency does not recur, and how the corrective action(s) will be monitored? The escutcheon plate on the sprinkler assembly in the Dietary Office was replaced. Sprinkler head and in-house fire inspections will be completed quarterly. The Director of Facilities Management will report the findings to the QAPI committee.