Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0363
D

Failure to Maintain Positive Latching of Corridor Doors

Pottstown, Pennsylvania Survey Completed on 01-15-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain the positive latching of corridor doors, specifically affecting the double doors to the Kitchen Dry Storage Room. During an observation on January 15, 2025, at 12:15 PM, it was noted that these doors did not automatically close in the required order, which resulted in their failure to latch within the frame. This issue was attributed to the malfunctioning of the associated door coordinator, which is essential for ensuring the doors close properly and maintain the necessary fire safety standards. An interview with the Facilities Director at the same time confirmed the observation, acknowledging that the doors failed to latch due to the door coordinator's failure. This deficiency impacts one of the eleven smoke compartments within the facility, highlighting a lapse in maintaining the required safety measures for corridor doors, which are crucial for preventing the passage of smoke and ensuring fire safety compliance.

Plan Of Correction

1. The Maintenance Director/designee will repair or replace the door coordinator on the double doors to the Kitchen Dry Storage Room to ensure proper closing and latching within the door frame. 2. The Maintenance Director and relevant staff members will receive training on NFPA 101 Standard - Corridor Doors, focusing on the importance of maintaining positive latching of corridor doors within smoke compartments. 3. The Maintenance Director/designee will inspect all corridor doors in the facility to verify proper latching within door frames. Special attention will be given to doors with coordinating devices. Monthly audits of corridor doors will be conducted to ensure continued compliance with positive latching requirements. Findings will be documented and reported for further action, if necessary. 4. Findings will be reviewed at the Quality Assurance Performance Improvement meeting.