Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0321
E

Deficient Hazardous Area Door Maintenance

Hanover, Pennsylvania Survey Completed on 02-12-2025

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain the integrity of hazardous area doors in two of seven smoke compartments. During an observation, it was noted that the basement Laundry Room's rated door had gaps exceeding the allowed 3/16 inch margin. This was confirmed in an interview with the Director of Maintenance. Additionally, another observation revealed that a hazardous area door on the 1st floor, located by the elevator and Nurses' Station, did not positively latch when closed. This issue was also confirmed by the Director of Maintenance.

Plan Of Correction

1. NGP9990 fire and smoke seal will be added to door. Second door was adjusted to ensure it positively latched. 2. Facility has conducted an audit to ensure other hazardous area doors compliance with regulation. 3. Maintenance director/designee will conduct monthly inspections of doors to ensure they positively latch, and gaps are within appropriate parameters. Audits will be reviewed at QAPI to ensure compliance.