Stay Ahead of Compliance with Monthly Citation Updates


In your State Survey window and need a snapshot of your risks?

Survey Preparedness Report

One Time Fee
$79
  • Last 12 months of citation data in one tailored report
  • Pinpoint the tags driving penalties in facilities like yours
  • Jump to regulations and pathways used by surveyors
  • Access to your report within 2 hours of purchase
  • Easily share it with your team - no registration needed
Get Your Report Now →

Monthly citation updates straight to your inbox for ongoing preparation?

Monthly Citation Reports

$18.90 per month
  • Latest citation updates delivered monthly to your email
  • Citations organized by compliance areas
  • Shared automatically with your team, by area
  • Customizable for your state(s) of interest
  • Direct links to CMS documentation relevant parts
Learn more →

Save Hours of Work with AI-Powered Plan of Correction Writer


One-Time Fee

$49 per Plan of Correction
Volume discounts available – save up to 20%
  • Quickly search for approved POC from other facilities
  • Instant access
  • Intuitive interface
  • No recurring fees
  • Save hours of work
K0211
E

Failure to Maintain Clear Means of Egress

Doylestown, Pennsylvania Survey Completed on 12-12-2024

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Summary

The facility failed to maintain the means of egress in compliance with NFPA 101 standards, as evidenced by two specific deficiencies. Firstly, during a document review, it was found that the headroom clearance of Exit Stairway Five leading to the attic was approximately 6'3", which is below the required minimum of 6'8". This deficiency was confirmed during an exit interview with the Administrator and Maintenance Director. Secondly, observations revealed obstructions in the exit pathways on two different floors. On the second floor, storage was found on the lower landing of the exit stairwell by the RNAC Office. Additionally, trash was observed on the landing of the exit stairwell next to resident room 216, and storage was found on the lower landing of the exit stairwell near resident room 108 on the first floor. These obstructions were also confirmed during the exit interview with the facility's administration.

Plan Of Correction

I am requesting the Department of Health do the FSES in this case. Facility is consulting Lenhardt Rodgers Architecture to assist with this citation. The second-floor exit stairwell by the RNAC Office was cleaned from storage on the lower landing. Maintenance staff to be educated on the importance of maintaining means of egress. Maintenance to monitor monthly or until compliance is met. Findings will be brought to the QAPI committee. Trash was cleaned from landing on the second-floor exit stairwell next to room 216. Storage was removed from the exit stairwell lower landing near room 108. Maintenance staff to be educated on the importance of maintaining means of egress. Maintenance to monitor monthly or until compliance is met. Findings will be brought to the QAPI committee.